MP73P+ : Battery charger/analyser
Operators Manual
set, at the preset time if the target voltage has not
been met.
Target Fail Time
Hours and
Minutes.
If a Max Charge Time has not been set the charge will
stop if this time is met before the target voltage has
been achieved. It will not switch to TopUp charge.
TopUp Amps
Amps.
If a TopUp charge is required this is the constant
current TopUp current. If no TopUp is required set to
zero.
TopUp Time
Time.
If a TopUp charge is required this is the length of the
TopUp.
Overcharge Volts. Volts.
During the TopUp charge the voltage can be detected
and stopped if the Overcharge Voltage is exceeded.
MULTI-STEP CHARGE
Value Required
Units
Description
Nominal Volts
Volts.
The battery nominal voltage is used to determine what
power supply setting to use and also the help validate
the data entered.
Charge Amps #1 Amps.
Constant current step #1 current.
Charge Time #1
Hours and
Minutes.
Constant current step #1 charge duration.
Charge Amps #2 Amps.
Constant current step #2 current.
Charge Time #2
Hours and
Minutes.
Constant current step #2 charge duration.
Charge Amps #3 Amps.
Constant current step #3 current.
Charge Time #3
Hours and
Minutes.
Constant current step #32 charge duration.
Charge Amps #4 Amps.
Constant current step #4 current.
Charge Time #4
Hours and
Minutes.
Constant current step #4 charge duration.
Overcharge Volts Volts.
Over charge voltage point to stop charge.
CELL MONITOR CC CHARGE
Value Required
Units
Description
Number of cells
1 to 20
The number of cells in the battery.
Target Volts
Volts.
This must be the cell target volts. When all cells are
above this value, but under the overcharge voltage,
the charge will move to the TopUp charge if one has