MP73P+ : Battery charger/analyser
Operators Manual
Press
ENT
to confirm.
Depending on the date format selected above the date and time will be requested one
at a time.
The clock will be set to these settings. Note the clock does not automatically adjust to
daylight saving time.
11.4
Modifying Display Intensity
The display on the unit has brightness control and this can be changed by pressing the
arrow key repeatedly to get to the level you require.
The setting is maintained even after power has been removed from the unit.
Note in some operations like data entry the display brightness cannot be changed.
11.5
Automatic screen dim
When the charger is left idle for more than 15 minutes the screen will automatically dim
to the lowest setting. Pressing any key will cause the display to revert back to the
original screen setting. This is to extend the life of the VFD display.
11.6
Printing battery serial number
The battery serial number can be included in the printed report. This is requested from
the operator when
START
or
DELAYED START
is selected.
By default the serial number on print option is turned off. To turn the request and print
of the battery serial number the default setting has to be changed.
Select SETTINGS -> SYSTEM -> MORE... -> BATT S/N
Select
>> NEXT >>
or
<< PREV <<
to change to either
: -
YES
NO
Press
ENT
to confirm.
If this is changed to
“yes”
then each time the
START
or
DELAYED START
is selected
the serial number will be requested. The previous serial number is remembered so
when working with the same battery in one session it does not need to be entered each
time. If the printer is not fitted this setting has no effect.
11.7
Cooling Fan
The charger is fitted with a cooling fan which is used to extract the heat energy
generated when charging and discharging. The fan in new units is automatically
controlled by the microprocessor to only operate when the charge of capacity test has
been started and switched it off after 10 minutes at end of charge or capacity test, or
when the heat-sink temperature falls below 40°C, which ever is the greater.
Doc: DWG1042-12-R18 MB73P+ Operators manual.odt
Page 57 of 64
Copyright Material of Intelligent Charging Limited © 2020
Printed On : 29/11/20