MP73P+ : Battery charger/analyser
Operators Manual
battery voltage detected is 3.0V greater than the
Target Volts
. Note this can
occur when a battery with a high impedance is connected to the unit. When
current is applied to the battery its voltage rises dramatically high.
•
CELL MONITOR OFFLINE
Applies to cell monitor charge and discharge modes only. It is an indication that
the cell monitor is either not connected or has failed.
•
ERROR IN CELL VOLTAGES
Applies to cell monitor charge and discharge modes only. This condition is
reported if any cell voltage read goes below –2.0V or above +2.0V It can be
caused by any of the cell input being disconnected. Use the cell monitor viewer
to check connections.
•
MAINS POWER FAILURE
This code will be displayed when a previous charge or discharge was
stopped because of mains power failure. Note: If a timed start was active
and the time had not elapsed the timed start will resume at the normal
time.
•
CELL BELOW TARGET
This code will be displayed when a cell monitor discharge which is used to obtain
low cell values has been executed and has terminated with one or more cells
below the target value.
11.2
Print Or Display Previous Operation Results
The unit can print or display the last operation data.
Select
SETTINGS
->
DISPLAY
or
->
PREVIOUS
The last test results are stored in battery backed memory so the previous test results
can be printed or displayed even if power had previously been removed from the unit.
11.3
Changing The Date Format And Date Time
The unit has a battery backed built in clock and calendar which is used to time stamp
test results and mark re-calibration events. It is important that the clock is set to the
correct format, date and time for your region.
Select
SETTINGS
->
SET CLOCK
Select
>> NEXT >>
or
<< PREV <<
to change to either
: -
dd/mm/yyyy
18/11/2019
mm/dd/yyyy
11/18/2019
yyyy/mm/dd
2019/11/18
yyyy/dd/mm
2019/18/11
dd mmm yyyy
18 Nov 2019
mmm dd yyyy