Intel RAID SRCU31 Users Guide
Coordinates of SCSI Devices
Host Adapter Number (HA)
The host adapter number assigned to the Intel RAID Controller SRCU31 is derived from the PCI
slot number of the Intel RAID Controller SRCU31. Therefore, if there is only one Intel RAID
Controller SRCU31 installed in the PCI bus computer system, the host adapter number is 0. If
there are two Intel RAID Controller SRCU31s installed, the Intel RAID Controller SRCU31 with
the lower PCI Slot number is assigned host adapter number 0 and the Intel RAID Controller
SRCU31 with the higher PCI slot number is assigned host adapter 1.
✏
NOTE
After a cold boot, the Intel RAID Controller SRCU31 BIOS displays two messages, each beginning
with the controller’s PCI slot number, for example, “[PCI 0/3] 4 MB RAM detected.” The number
after the “/” is the slot number of the controller. This will help determine the order of the Intel
RAID Controller SRCU31s and which host adapter number is assigned to them by UnixWare.
UnixWare Bus Number, Target ID and LUN
Target IDs and LUNs for “Non-Direct Access Devices” (devices like streamers, tapes and
CD-ROMs and therefore not configurable via StorCon), are directly assigned to the SCSI ID and
the channel of the Intel RAID Controller SRCU31. Host drives are assigned in increasing order to
the free coordinates (bus number and target ID; LUN is always 0).
Configuration Example
In the PCI computer are two Intel RAID Controller SRCU31s (HA 0 = First Intel RAID Controller
SRCU31, HA 1 = Second Intel RAID Controller SRCU31), each with two SCSI channels.
1 Hard Disk Drive
as host drive no. 0 on HA0
1 Hard Disk Drive
as host drive no. 0 on HA1
1 Hard Disk Drive
as host drive no. 1 on HA1
1 Streamer
SCSI ID 2, LUN 0 on SCSI channel A of HA0
1 CD-ROM
SCSI ID 3, LUN 0 on SCSI channel B of HA0
1 DAT
SCSI ID 2, LUN 0 on SCSI channel A of HA1
The resulting HA, Bus, Target ID, and LUN are indicated in Table 13.
Summary of Contents for SRCU31
Page 1: ...Intel RAID Controller SRCU31 User s Guide Order Number A78134 001...
Page 22: ...22 Intel RAID SRCU31 Users Guide...
Page 35: ...Getting Started 35 Figure 7 Operational State Diagram for RAID 4 5...
Page 46: ...46 Intel RAID SRCU31 Users Guide...
Page 62: ...62 Intel RAID SRCU31 Users Guide...
Page 76: ...76 Intel RAID SRCU31 Users Guide...
Page 110: ...110 Intel RAID SRCU31 Users Guide Figure 47 Block Diagram of a SAF TE Subsystem...
Page 163: ...Storage Console Plus 163 Figure 104 StorCon Help...
Page 166: ...166 Intel RAID SRCU31 Users Guide Figure 106 RAID Configuration Service Add Remove Users...
Page 168: ...168 Intel RAID SRCU31 Users Guide Figure 108 Log File Name Figure 109 Workstation Names...
Page 170: ......
Page 178: ...178 Intel RAID SRCU31 Users Guide...
Page 182: ...182 Intel RAID SRCU31 Users Guide...