After pressing <Enter>, StorCon displays a list of possible RAID levels. See Figure 58. Then
StorCon prompts you for the stripe size. This is the size of the stripes into which the data is
divided. Valid values are 16KB, 32KB, 64KB or 128KB. The default is 128KB. See Figure 59.
Figure 58. Choose Type
Figure 59. Strip Size
The Build Type decides how the redundancy information is created. The Destructive Build (only
available if StorCon was loaded with <Ctrl> + <G>) fills all hard disk drives with “0” and no
further parity calculation is necessary. This build method is pretty fast, but the build must be
successfully finished before you can leave StorCon (otherwise the build mode is automatically
changed to Non-destructive during the next boot). The Non-destructive build calculates the
redundancy information from the contents of the data stripes. It takes longer, but can run in the
background, for example, during the installation of the operating system. See Figure 60.
Figure 60. Choose Build Type
A warning displays that all data will be destroyed after confirmation. (Figure 61). Confirm the
choice by pressing <Y>. The array drive is created.
Figure 61. Create Array Drive Confirmation
Summary of Contents for SRCU31
Page 1: ...Intel RAID Controller SRCU31 User s Guide Order Number A78134 001...
Page 22: ...22 Intel RAID SRCU31 Users Guide...
Page 35: ...Getting Started 35 Figure 7 Operational State Diagram for RAID 4 5...
Page 46: ...46 Intel RAID SRCU31 Users Guide...
Page 62: ...62 Intel RAID SRCU31 Users Guide...
Page 76: ...76 Intel RAID SRCU31 Users Guide...
Page 110: ...110 Intel RAID SRCU31 Users Guide Figure 47 Block Diagram of a SAF TE Subsystem...
Page 163: ...Storage Console Plus 163 Figure 104 StorCon Help...
Page 166: ...166 Intel RAID SRCU31 Users Guide Figure 106 RAID Configuration Service Add Remove Users...
Page 168: ...168 Intel RAID SRCU31 Users Guide Figure 108 Log File Name Figure 109 Workstation Names...
Page 170: ......
Page 178: ...178 Intel RAID SRCU31 Users Guide...
Page 182: ...182 Intel RAID SRCU31 Users Guide...