The Reassigns Counter
The Reassigns counter records the number of media defects which occur on a hard disk drive.
Defective blocks of a hard disk drive are assigned substitute blocks (spare blocks) that are either on
the same track, or on alternate ones if all spare blocks on the same track are already in use. The
administration of the reassignments is carried out by the hard disk drive through reassignment
tables. If you observe that the number of reassigns is constantly increasing, you may assume that
something is wrong with the drive.
If a hard disk drive works with alternate tracks, it is generally no longer suitable for applications
with high performance expectations. Whenever a defective block is being accessed, the read/write
actuator has to move to an alternate position and this requires extra time.
The Grown Defects Counter
The Grown Defects counter records the number of media defects that have occurred since the
device was first operated with an Intel RAID Controller SRCU31. A hard disk drive is in good
condition when it has 0 grown defects. Any value greater than 0 indicates a grown defect
condition. For more information on grown defects see Chapter 7, View Status/Defects.
Last Status
Last Status information should always be 0x00000000. After a device failure or other significant
events, a different value may be displayed here. This value is volatile and is reset to 0x00000000
after each power up and/or reset. If you press <Enter> on a Drive, StorCon displays additional
information on the SCSI parameter settings, as shown in Figure 21.
Figure 21. Hard Disk Drive Last Status
Summary of Contents for SRCU31
Page 1: ...Intel RAID Controller SRCU31 User s Guide Order Number A78134 001...
Page 22: ...22 Intel RAID SRCU31 Users Guide...
Page 35: ...Getting Started 35 Figure 7 Operational State Diagram for RAID 4 5...
Page 46: ...46 Intel RAID SRCU31 Users Guide...
Page 62: ...62 Intel RAID SRCU31 Users Guide...
Page 76: ...76 Intel RAID SRCU31 Users Guide...
Page 110: ...110 Intel RAID SRCU31 Users Guide Figure 47 Block Diagram of a SAF TE Subsystem...
Page 163: ...Storage Console Plus 163 Figure 104 StorCon Help...
Page 166: ...166 Intel RAID SRCU31 Users Guide Figure 106 RAID Configuration Service Add Remove Users...
Page 168: ...168 Intel RAID SRCU31 Users Guide Figure 108 Log File Name Figure 109 Workstation Names...
Page 170: ......
Page 178: ...178 Intel RAID SRCU31 Users Guide...
Page 182: ...182 Intel RAID SRCU31 Users Guide...