Low Voltage Differential (LVD) Support
The Intel RAID Controller SRCU31 supports Ultra-2 LVD SCSI operating at up to 80MB/sec and
Ultra160 LVD SCSI operating at up to 160MB/sec.
Table 7.
Supported SCSI Hard Disk Drive Standards
Maximum Cable Length
(meters)
(1)
SCSI Drive
Standard
Speed
(MB/Sec)
Bus Width
(Bits)
SE
LVD
Adapter Maximum
Devices per SCSI
Channel
SCSI-1
(2)
5 8 6 NA
(3)
8
Fast SCSI
(2)
10 8
3
NA
(3)
8
Fast Wide SCSI
20
16
3
NA
(3)
16
Ultra SCSI
(2)
20
8
1.5 NA
(3)
8
Ultra SCSI
(2)
20
8
3
NA
4
Wide Ultra SCSI
40
16
NA
NA
(3)
16
Wide Ultra SCSI
40
16
1.5
NA
8
Wide Ultra SCSI
40
16
3
NA
4
Ultra2 SCSI
(2, 4)
40
8
NA
(4)
12 8
Wide Ultra2
(4)
80
16
NA
(4)
12
16
Ultra160 (Ultra3)
160
16
NA
(4)
12
16
NOTES:
1.
May be exceeded in Point-to-Point and engineered specific applications.
2.
Use of the word “Narrow,” preceding SCSI, Ultra SCSI, or Ultra2 SCSI (for example, Narrow SCSI) is
optional.
3.
LVD was not defined in the original SCSI standards for this speed. If all devices on the bus support LVD,
then 12-meters operation is possible at this speed. However, if any device on the bus is single-ended
only, then the entire bus switches to single-ended mode and the distances in the single-ended column
apply.
4.
Single-ended is not defined for speeds beyond Ultra.
5.
After Ultra2, all new speeds are wide only.
The preceding information is based on the “STA-Endorsed Terms & Terminology for SCSI Parallel
Interface Technology” specification published by the SCSI Trade Association. It can be viewed at:
http//www.scsita.org/terms/scsiterms.html
SCSI Connectors
The Intel RAID Controller SRCU31 includes two internal SCSI-3 Ultra Wide 68-pin connectors
and two external VHDCI (Very High Density Connector Interface) 68-pin connectors. Each
connector can be fully populated with up to 15 SCSI devices (not to exceed an additive total of
15 devices per channel when using both he internal and external connector for the channel) as long
as cable length limitations for each segment are not exceeded.
Summary of Contents for SRCU31
Page 1: ...Intel RAID Controller SRCU31 User s Guide Order Number A78134 001...
Page 22: ...22 Intel RAID SRCU31 Users Guide...
Page 35: ...Getting Started 35 Figure 7 Operational State Diagram for RAID 4 5...
Page 46: ...46 Intel RAID SRCU31 Users Guide...
Page 62: ...62 Intel RAID SRCU31 Users Guide...
Page 76: ...76 Intel RAID SRCU31 Users Guide...
Page 110: ...110 Intel RAID SRCU31 Users Guide Figure 47 Block Diagram of a SAF TE Subsystem...
Page 163: ...Storage Console Plus 163 Figure 104 StorCon Help...
Page 166: ...166 Intel RAID SRCU31 Users Guide Figure 106 RAID Configuration Service Add Remove Users...
Page 168: ...168 Intel RAID SRCU31 Users Guide Figure 108 Log File Name Figure 109 Workstation Names...
Page 170: ......
Page 178: ...178 Intel RAID SRCU31 Users Guide...
Page 182: ...182 Intel RAID SRCU31 Users Guide...