100
Intel RAID SRCU31 Users Guide
After confirmation, the failed drive must be removed from the system and the new one configured
on the same ID and installed in the system. See Figure 32 and Figure 33.
Figure 32. Select Drive to Repair
Figure 33. Replace Hard Disk Drive Prompt
StorCon detects the new drive and expects clearance to build this drive as a replacement into the
array drive. See Figure 34.
Figure 34. Add Disk to Array Confirmation
When clearance is given, the state of the array drive changes to “Rebuild,” for example, the missing
data is reconstructed out of the remaining data and redundancy information. See Figure 35.
Figure 35. Array Drive Summary
The Error state of an array drive is critical. There are several procedures in the Intel RAID
Controller SRCU31’s firmware to handle such cases and bring back the array drive into operation
without losing data. See Figure 36.
Figure 36. Array Drive Error State Dialog
Summary of Contents for SRCU31
Page 1: ...Intel RAID Controller SRCU31 User s Guide Order Number A78134 001...
Page 22: ...22 Intel RAID SRCU31 Users Guide...
Page 35: ...Getting Started 35 Figure 7 Operational State Diagram for RAID 4 5...
Page 46: ...46 Intel RAID SRCU31 Users Guide...
Page 62: ...62 Intel RAID SRCU31 Users Guide...
Page 76: ...76 Intel RAID SRCU31 Users Guide...
Page 110: ...110 Intel RAID SRCU31 Users Guide Figure 47 Block Diagram of a SAF TE Subsystem...
Page 163: ...Storage Console Plus 163 Figure 104 StorCon Help...
Page 166: ...166 Intel RAID SRCU31 Users Guide Figure 106 RAID Configuration Service Add Remove Users...
Page 168: ...168 Intel RAID SRCU31 Users Guide Figure 108 Log File Name Figure 109 Workstation Names...
Page 170: ......
Page 178: ...178 Intel RAID SRCU31 Users Guide...
Page 182: ...182 Intel RAID SRCU31 Users Guide...