158
Intel RAID SRCU31 Users Guide
The Idle State
This state is characterized by the fact that the redundant information of the array drive has never
been entirely created. The array drive is in this state after its first configuration. Should an error
occur while the array is in the build state, the array returns to the idle state Exception: if during
build mode the dedicated drive of a RAID 4 array drive fails, the state changes to
fail
.
Figure 96. The Idle State
The Build / Rebuild State
After the array drive has been configured for the first time, and the build process has begun the
array drive assumes the build state. While the array drive is in the build state, redundancy
information is calculated and stored to the components of the array drive.
The disk array will assume the rebuild state after the automatic activation of a hot fix drive or after
a manual replacement (hot plug). The data and the redundant information are reconstructed and
stored to the new drive.
While in the build and rebuild states, the array drive is not redundant.
You can monitor the progress of the array build/rebuild by clicking the right mouse button on the
host drive and then selecting progress information.
✏
NOTE
User traffic on an array drive that is in the build/rebuild state, slows down the build/rebuild
process.
Figure 97. The Build / Rebuild State
Summary of Contents for SRCU31
Page 1: ...Intel RAID Controller SRCU31 User s Guide Order Number A78134 001...
Page 22: ...22 Intel RAID SRCU31 Users Guide...
Page 35: ...Getting Started 35 Figure 7 Operational State Diagram for RAID 4 5...
Page 46: ...46 Intel RAID SRCU31 Users Guide...
Page 62: ...62 Intel RAID SRCU31 Users Guide...
Page 76: ...76 Intel RAID SRCU31 Users Guide...
Page 110: ...110 Intel RAID SRCU31 Users Guide Figure 47 Block Diagram of a SAF TE Subsystem...
Page 163: ...Storage Console Plus 163 Figure 104 StorCon Help...
Page 166: ...166 Intel RAID SRCU31 Users Guide Figure 106 RAID Configuration Service Add Remove Users...
Page 168: ...168 Intel RAID SRCU31 Users Guide Figure 108 Log File Name Figure 109 Workstation Names...
Page 170: ......
Page 178: ...178 Intel RAID SRCU31 Users Guide...
Page 182: ...182 Intel RAID SRCU31 Users Guide...