140
Intel RAID Controller SRCMR User’s Guide
✏
NOTE
To select a transfer rate above 10 MB/s the protocol must be set to SCSI-III. Higher frequencies
(single ended SCSI) require better cabling, shorter cables and a professional termination
terms_termination of the SCSI bus.
Disconnect
This SCSI feature enables a SCSI device to disconnect from the SCSI bus. By releasing the SCSI
bus while the device doesn’t need it, the bus becomes free for other devices to transfer or receive
data. An example of a disconnect situation is a hard disk that needs time to read data from its
media after receiving a read command. It may then disconnect from the SCSI bus so that other
devices can transfer data. Later on it reconnects when it is able to deliver the data instantly. You
can change the disconnect setting for a hard disk in the SCSI parameters / Initialize menu
pdisk_parameters.
Tagged Queues
This feature enables modern hard disk drives to receive several commands at one time and then
process them in an optimized order. A few, mainly older drives, do not support this feature. You
can change the tagged queues setting for a hard disk in the SCSI parameters/Initialize menu
pdisk_parameters.
SCSI Read Cache / SCSI Write Cache
These settings enable or disable the write and read caches of the hard disks. Turning these caches
OFF degrades the performance of the hard disk. You can change the cache settings of a drive in the
SCSI parameters / Initialize menu pdisk_parameters.
De-initialize a Physical Disk
De-initializing a physical drive removes the Intel RAID Controller SRCMR initialization sectors
terms_initialization. The physical drive cannot be member of a logical drive once it is deinitialized.
Lock / Unlock a Removable Disk
With this function you can lock or unlock a removable drive containing a removable medium. If
the physical drive is locked, the medium cannot be ejected with the eject button while the system is
running.
Summary of Contents for SRCMR
Page 1: ...Intel RAID Controller SRCMR User s Guide Order Number A75271 001...
Page 32: ...32 Intel RAID Controller SRCMR User s Guide Figure 8 Operational State Diagram...
Page 44: ...44 Intel RAID Controller SRCMR User s Guide...
Page 52: ...52 Intel RAID Controller SRCMR User s Guide...
Page 68: ...68 Intel RAID Controller SRCMR User s Guide...
Page 109: ...Storage Console 109 Figure 49 Block Diagram of a SAF TE Subsystem...
Page 122: ...122 Intel RAID Controller SRCMR User s Guide...
Page 138: ...138 Intel RAID Controller SRCMR User s Guide Figure 86 Physical Drive Information...
Page 166: ...166 Intel RAID Controller SRCMR User s Guide Figure 107 StorCon Help...
Page 169: ...Storage Console Plus 169 Figure 110 RAID Configuration Service Add Remove Users...
Page 171: ...Storage Console Plus 171 Figure 113 Workstation Names...
Page 180: ...180 Intel RAID Controller SRCMR User s Guide...