118
Intel RAID Controller SRCMR User’s Guide
After pressing <Enter>, StorCon displays a list of possible RAID levels. See Figure 60. Then
StorCon prompts you for the stripe size. This is the size of the stripes into which the data is
divided. Valid values are 16KB, 32KB, 64KB or 128KB. The default is 128KB. See Figure 61.
Figure 60. Choose Type
Figure 61. Strip Size
The Build Type decides how the redundancy information is created. The Destructive Build (only
available if StorCon was loaded with <Ctrl>+<g>) fills all hard disks with “0” and no further parity
calculation is necessary. This build method is pretty fast, but the build must be successfully
finished before you can leave StorCon (otherwise the build mode is automatically changed to
Non-destructive during the next boot). The Non-destructive build calculates the redundancy
information from the contents of the data stripes. It takes longer, but can run in the background, for
example, during the installation of the operating system. See Figure 62.
Figure 62. Choose Build Type
A warning displays that all data will be destroyed after confirmation. (Figure 63). Confirm your
choice by pressing <Y>. The array drive is created.
Figure 63. Create Array Drive Confirmation
Summary of Contents for SRCMR
Page 1: ...Intel RAID Controller SRCMR User s Guide Order Number A75271 001...
Page 32: ...32 Intel RAID Controller SRCMR User s Guide Figure 8 Operational State Diagram...
Page 44: ...44 Intel RAID Controller SRCMR User s Guide...
Page 52: ...52 Intel RAID Controller SRCMR User s Guide...
Page 68: ...68 Intel RAID Controller SRCMR User s Guide...
Page 109: ...Storage Console 109 Figure 49 Block Diagram of a SAF TE Subsystem...
Page 122: ...122 Intel RAID Controller SRCMR User s Guide...
Page 138: ...138 Intel RAID Controller SRCMR User s Guide Figure 86 Physical Drive Information...
Page 166: ...166 Intel RAID Controller SRCMR User s Guide Figure 107 StorCon Help...
Page 169: ...Storage Console Plus 169 Figure 110 RAID Configuration Service Add Remove Users...
Page 171: ...Storage Console Plus 171 Figure 113 Workstation Names...
Page 180: ...180 Intel RAID Controller SRCMR User s Guide...