Storage Console
95
Host Drive Options
Select a host drive and press <Enter> to open the host drive options dialog (Figure 30).
Figure 30. Host Drive Options
Change Drive Name:
Use Change Drive Name to change the name of a host drive. The name serves to identify a host
drive with StorCon. For example, you could name the boot host drive “Boot” and the data host
drive “Data”.
Swap Host Drives:
When a PCI computer is switched on, the host drives are initialized in the order of the host drive
list, which means that the operating system is booted from the host drive with the lowest number.
For reasons of flexibility, a host drive’s position in the list can be changed. However, the position
of the host drive from which the operating system is booted and the position of the host drive from
which StorCon (disk version) was started (both can be the same), cannot be changed. If you wish
to change the position of these drives, you have to boot the operating system and StorCon from a
floppy disk or use StorCon from the Flash-RAM of the Intel RAID Controller SRCMR. To change
the position of a host drive in the host drive list, highlight the host drive and confirm with <Enter>.
Then, type in the new position and press <Enter>.
Remove Host Drives:
Removing a host drive results in the loss of all data.
All data will be lost after removal
. If you
remove a host drive belonging to an array drive for which several host drives exist (after capacity
expansion, or after splitting), all other host drives will also be removed.
Split Host Drive:
For some purposes you might need to split an existing host drive into two or several host drives, in
which case each host drive looks like a single hard disk to the operating system. Since the new host
drives have smaller capacities, StorCon has to write new header information on the host drives.
All
data will be lost from the original host drive
.
The Split Host Drive menu is only available if StorCon is loaded with <Ctrl>+<g> from the Intel
RAID Controller SRCMR’s Flash-RAM.
Summary of Contents for SRCMR
Page 1: ...Intel RAID Controller SRCMR User s Guide Order Number A75271 001...
Page 32: ...32 Intel RAID Controller SRCMR User s Guide Figure 8 Operational State Diagram...
Page 44: ...44 Intel RAID Controller SRCMR User s Guide...
Page 52: ...52 Intel RAID Controller SRCMR User s Guide...
Page 68: ...68 Intel RAID Controller SRCMR User s Guide...
Page 109: ...Storage Console 109 Figure 49 Block Diagram of a SAF TE Subsystem...
Page 122: ...122 Intel RAID Controller SRCMR User s Guide...
Page 138: ...138 Intel RAID Controller SRCMR User s Guide Figure 86 Physical Drive Information...
Page 166: ...166 Intel RAID Controller SRCMR User s Guide Figure 107 StorCon Help...
Page 169: ...Storage Console Plus 169 Figure 110 RAID Configuration Service Add Remove Users...
Page 171: ...Storage Console Plus 171 Figure 113 Workstation Names...
Page 180: ...180 Intel RAID Controller SRCMR User s Guide...