Installing Linux
57
GDT Driver Parameters
Reservation of SCSI Devices
The reservation of SCSI devices becomes necessary if you want Direct Access Devices (for
example, hard disks, removable hard disks like IOMEGA or SyQuest, some MOs) to be directly
controlled by Linux and not the Intel RAID Controller SRCMR’s firmware (for example, they are
not configured as host drives).
Reservation of SCSI devices is also called raw-service. In this case the Intel RAID Controller
SRCMR does not cache the data to/from the reserved SCSI device. This reservation is important
for removable hard disks. If they are controlled by the Intel RAID Controller SRCMR and are a
host drive, a media change is very difficult.
Non Direct Access Devices like CD-ROMs, Streamers, DATs, etc. do NOT require a reservation.
CAUTION
The reservation of SCSI devices is only possible with not-initialized SCSI devices. (Use StorCon to
de-initialize an already initialized device).
From driver version 1.10 on you can add the parameters for the reservation with the LILO append
command:
Excerpt of /etc/lilo.conf:
# End LILO global section
# Linux bootable partition config begins
image = /boot/vmlinuz
root = /dev/sda2
label = Linux
append = “gdth=reserve_list:1,0,6,0”
# Linux bootable partition config ends
This gdth driver parameter reserves the SCSI device that is connected with Intel RAID Controller
SRCMR 1 (the second Intel RAID Controller SRCMR), SCSI Bus 0 (channel A), ID 6, LUN 0 for
Linux (raw service).
After each change in /etc/lilo.conf lilo must be loaded once.
Driver parameters may also be entered at the LILO boot prompt. (for example:
gdth=reserve_list:1,0,6,0).
Summary of Contents for SRCMR
Page 1: ...Intel RAID Controller SRCMR User s Guide Order Number A75271 001...
Page 32: ...32 Intel RAID Controller SRCMR User s Guide Figure 8 Operational State Diagram...
Page 44: ...44 Intel RAID Controller SRCMR User s Guide...
Page 52: ...52 Intel RAID Controller SRCMR User s Guide...
Page 68: ...68 Intel RAID Controller SRCMR User s Guide...
Page 109: ...Storage Console 109 Figure 49 Block Diagram of a SAF TE Subsystem...
Page 122: ...122 Intel RAID Controller SRCMR User s Guide...
Page 138: ...138 Intel RAID Controller SRCMR User s Guide Figure 86 Physical Drive Information...
Page 166: ...166 Intel RAID Controller SRCMR User s Guide Figure 107 StorCon Help...
Page 169: ...Storage Console Plus 169 Figure 110 RAID Configuration Service Add Remove Users...
Page 171: ...Storage Console Plus 171 Figure 113 Workstation Names...
Page 180: ...180 Intel RAID Controller SRCMR User s Guide...