Getting Started
31
Operational States of an Intel RAID Controller SRCMR
Firmware Disk Array
Operational States for RAID 4/5
An array drive under the Intel RAID Controller SRCMR firmware operating system can assume
seven different operational states: Idle, Ready, Fail, Build, Rebuild, Expand and Error.
Table 9.
Operational States
State
Description
Idle State
This state is characterized by the fact that the redundant information of the disk
array has never been entirely created. The disk array is in this state after its first
configuration and until you quit Storage Console (StorCon). Should an error occur
while the array is in the build state, the array returns to the Idle state (exception: if
during build state the dedicated drive of RAID 4 fails, the state changes to fail.
Build State
After the disk array has been configured for the first time, it assumes the build state
as soon as you quit StorCon. While the array is in the build state, redundancy
information is calculated and stored to the hard disks of the array.
Ready State
The disk array is fully operational when in the ready state. All redundant
information is present, that is, a hard disk can fail without impairing the functionality
of the disk array. This is the normal state of a disk array. The state ready/expand
indicates that the RAID level and/or capacity are currently migrated/expanded.
Fail State
The disk array changes to the fail state whenever a Logical Drive fails.
Redundancy information is still present, thus allowing the remaining hard disks to
continue working. This state should be eliminated as soon as possible by replacing
the defective hard disk. If a so-called Hot Fix drive has previously been assigned
to a disk array with StorCon, the controller will automatically replace the defective
drive and start the reconstruction of the data and the redundant information.
Therefore, under these circumstances the fail state is only temporary and will be
eliminated by the controller itself.
Rebuild State
The disk array will assume this state after the automatic activation of a Hot Fix
drive or after a manual replacement is carried out with StorCon. The data and the
redundant information are reconstructed and stored to the new drive.
Expand State
If the capacity or RAID level of an existing disk array is changed, the disk array
changes its state into expand. As soon as the expansion or migration is
completed, the state changes back to ready.
Summary of Contents for SRCMR
Page 1: ...Intel RAID Controller SRCMR User s Guide Order Number A75271 001...
Page 32: ...32 Intel RAID Controller SRCMR User s Guide Figure 8 Operational State Diagram...
Page 44: ...44 Intel RAID Controller SRCMR User s Guide...
Page 52: ...52 Intel RAID Controller SRCMR User s Guide...
Page 68: ...68 Intel RAID Controller SRCMR User s Guide...
Page 109: ...Storage Console 109 Figure 49 Block Diagram of a SAF TE Subsystem...
Page 122: ...122 Intel RAID Controller SRCMR User s Guide...
Page 138: ...138 Intel RAID Controller SRCMR User s Guide Figure 86 Physical Drive Information...
Page 166: ...166 Intel RAID Controller SRCMR User s Guide Figure 107 StorCon Help...
Page 169: ...Storage Console Plus 169 Figure 110 RAID Configuration Service Add Remove Users...
Page 171: ...Storage Console Plus 171 Figure 113 Workstation Names...
Page 180: ...180 Intel RAID Controller SRCMR User s Guide...