Local Mounted Cluster Drive
A Local Mounted Cluster Drive is a host drive on a clustering I/O channel. This host drive is
mounted on the selected Intel RAID Controller SRCMR on a local server.
Clustering means that two or more servers share resources. If one server fails its resources move to
another valid server. The hard disks used for clustering are physically connected not with just one
Intel RAID Controller SRCMR, but with several Intel RAID Controller SRCMRs in different
servers (shared I/O channels).
Only one server can own a host drive at the same time, so a host drive configured for clustering
may either be controlled by the selected Intel RAID Controller SRCMR (for example, local
mounted) or by a different Intel RAID Controller SRCMR (for example, remote mounted). You
may only change the configuration of a local mounted host drive.
Remote Mounted Cluster Drive
A
Remote Mounted Cluster Drive
is a host drive on a clustering I/O channel. This host drive is
mounted on an Intel RAID Controller SRCMR in a different server.
Clustering means that two or more servers share resources. If one server fails its resources move to
another valid server. The hard disks used for clustering are physically not connected with just one
Intel RAID Controller SRCMR, but with several Intel RAID Controller SRCMRs in different
servers (shared I/O channels).
Only one server can own a host drive at the same time, so a host drive configured for clustering
may either be controlled by the selected Intel RAID Controller SRCMR (for example, local
mounted) or by a different Intel RAID Controller SRCMR (for example, remote mounted). You
may only change the configuration of a local mounted host drive.
Summary of Contents for SRCMR
Page 1: ...Intel RAID Controller SRCMR User s Guide Order Number A75271 001...
Page 32: ...32 Intel RAID Controller SRCMR User s Guide Figure 8 Operational State Diagram...
Page 44: ...44 Intel RAID Controller SRCMR User s Guide...
Page 52: ...52 Intel RAID Controller SRCMR User s Guide...
Page 68: ...68 Intel RAID Controller SRCMR User s Guide...
Page 109: ...Storage Console 109 Figure 49 Block Diagram of a SAF TE Subsystem...
Page 122: ...122 Intel RAID Controller SRCMR User s Guide...
Page 138: ...138 Intel RAID Controller SRCMR User s Guide Figure 86 Physical Drive Information...
Page 166: ...166 Intel RAID Controller SRCMR User s Guide Figure 107 StorCon Help...
Page 169: ...Storage Console Plus 169 Figure 110 RAID Configuration Service Add Remove Users...
Page 171: ...Storage Console Plus 171 Figure 113 Workstation Names...
Page 180: ...180 Intel RAID Controller SRCMR User s Guide...