Replacing the Front Panel Board (SR1530AH/
SR1530AHLX)
Caution: The control panel is NOT hot swappable. Before removing or replacing the control panel,
you must first take the server out of service, turn off all peripheral devices connected to
the system, turn off the system by pressing the power button, and unplug the AC power
cord from the system or wall outlet.
Your server must be operated with a control panel installed.
1. Observe the safety and ESD precautions at the beginning of this book. See
“Safety
Information” on page iii
.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the server system cover. For instructions, see
“Removing the Server
System Cover” on page 28
.
4. Disconnect the power and data cables connected to HDD1, at the right side of the
system. It is not necessary to remove the HDD1 drive.
5. Disconnect the front panel cable and the USB cable from the front panel board.
6. Remove the two screws that attach the front panel board to the server system. See
letter “A” in the figure below. Save these screws. You will re-install them later.
7. Lift the front panel board from the system. See letter “B” in the figure.
Figure 72. Removing Front Panel Board from the Server System (SR1530AH/
SR1530AHLX)
A
B
AF000967
Summary of Contents for SR1530 - AHJPCIERISER PCI-E x8 Riser Card
Page 6: ...vi Intel Server System SR1530AH SR1530AHLX SR1530HAHLX User s Guide...
Page 16: ...xvi Intel Server System SR1530AH SR1530AHLX...
Page 18: ...xviii Intel Server System SR1530AH SR1530AHLX...
Page 22: ...xxii Intel Server System SR1530AH SR1530AHLX...
Page 40: ...18 Intel Server System SR1530AH SR1530AHLX SR1530HAHLX...
Page 46: ...24 Intel Server System SR1530AH SR1530AHLX SR1530HAHLX...
Page 144: ...122 Intel Server System SR1530AH SR1530AHLX SR1530HAHLX...
Page 168: ...146 Intel Server System SR1530AH SR1530AHLX SR1530HAHLX...
Page 180: ...158 Intel Server System SR1530AH SR1530AHLX SR1530HAHLX...
Page 184: ...162 Intel Server System SR1530AH SR1530AHLX SR1530HAHLX...