Page 1: ...Intel Server System SR1530AH SR1530AHLX SR1530HAHLX User s Guide A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies Products Intel Order Number D59196 002...

Page 2: ...h may occur Intel may make changes to specifications and product descriptions at any time without notice Intel server boards contain a number of high density VLSI and power delivery components that ne...

Page 3: ...nt Toolkit 2 0 CD oder unter http support intel com support motherboards server sb cs 010770 htm Consignes de s curit Lisez attention toutes les consignes de s curit et les mises en garde indiqu es da...

Page 4: ...iv Intel Server System SR1530AH SR1530AHLX SR1530HAHLX User s Guide http support intel com support motherboards server sb CS 010770 htm Intel Server Boards and Server Chassis Safety Information Intel...

Page 5: ...quipment damage can result Electrostatic discharge ESD and ESD protection ESD can damage disk drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD...

Page 6: ...vi Intel Server System SR1530AH SR1530AHLX SR1530HAHLX User s Guide...

Page 7: ...ify components and their locations Chapter 2 provides instructions on using the utilities that are shipped with the board or that may be required to update the system This includes how to navigate thr...

Page 8: ...sive heat sink mounted behind the hard drives next to the blower fans in the server system One hard disk drive 0 bracket in the server system product box One hard disk drive 1 bracket installed in the...

Page 9: ...m product box Screws 6 32 flat head screws for attaching the slimline optical drive and hard disk drives to the chassis and for attaching hard disk drives to the hard disk drive brackets One 6 32 pan...

Page 10: ...530AH SR1530AHLX SR1530HAHLX Quick Start User s Guide Found in the product box Virtual system tours and interactive repair information A link to the SMaRT Tool is available under Other Resources at th...

Page 11: ...r System Features 1 Chassis Component Identification 5 System Front Panel SR1530AH SR1530AHLX 5 System Front Panel SR1530HAHLX 6 System Rear 7 Peripheral Devices SR1530AH SR1530AHLX 8 Peripheral Devic...

Page 12: ...rd Disk Drive SR1530AH SR1530AHLX 41 Removing a Hard Disk Drive SR1530AH SR1530AHLX 45 Installing and Removing a Hot Swap SATA Drive SR1530HAHLX 47 Installing a Hot Swap SATA Drive SR1530HAHLX 47 Remo...

Page 13: ...ut Voltages 99 350W Single Power Supply Output Voltages 99 System Environmental Specifications 100 Appendix B Troubleshooting 101 Resetting the System 101 Problems following Initial System Installatio...

Page 14: ...eutsch 128 Sicherheitshinweise f r den Server 128 Sicherheitshinweise und Vorsichtsma nahmen 128 Zielbenutzer der Anwendung 129 Standortauswahl 129 Handhabung von Ger ten 129 Warnungen zu Netzspannung...

Page 15: ...ory and Compliance Information 147 Product Regulatory Compliance 147 Product Safety Compliance 147 Product EMC Compliance Class A Compliance 148 Certifications Registrations Declarations 149 Product R...

Page 16: ...xvi Intel Server System SR1530AH SR1530AHLX...

Page 17: ...530AHLX SR1530HAHLX Feature Summary 2 Table 3 NIC LED Descriptions 7 Table 4 Setup Menu Key Use 20 Table 5 Power Supply Output Capability 99 Table 6 System Environmental Specifications 100 Table 7 Res...

Page 18: ...xviii Intel Server System SR1530AH SR1530AHLX...

Page 19: ...the Processor Air Duct SR1530HAHLX 32 Figure 22 Installing the Processor Air Duct SR1530AH SR1530AHLX 33 Figure 23 Installing the Processor Air Duct SR1530HAHLX 34 Figure 24 Installing the Memory 35...

Page 20: ...9 Figure 65 Replacing the CMOS Battery 71 Figure 66 Disconnecting Power Cables SR1530AH SR1530AHLX 73 Figure 67 Removing Power Supply from the Server System SR1530AH SR1530AHLX 74 Figure 68 Installing...

Page 21: ...System SR1530AH SR1530AHLX xxi Figure 87 Removing the Rack Handle 94 Figure 88 Power Cable Routing SR1530AH SR1530AHLX 96 Figure 89 Data Cable Routing SR1530AH SR1530AHLX 97 Figure 90 Cable Routing SR...

Page 22: ...xxii Intel Server System SR1530AH SR1530AHLX...

Page 23: ...the server system features and diagrams showing the location of important components and connections on the server system Figure 1 Intel Server System SR1530AH SR1530AHLX Note The figure above is sho...

Page 24: ...23 pounds 10 43 kilograms Server Board One of the following Intel Server System SR1530AH Intel Server Board S3000AH Intel Server Systems SR1530AHLX SR1530HAHLX Intel Server Board S3000AHLX Processor...

Page 25: ...rver System SR1530AH Intel 10 100 1000 82573V Gigabit Ethernet Controller Intel Server System SR1530AHLX Intel 10 100 1000 82573E Gigabit Ethernet Controller Expansion Capabilities optional accessory...

Page 26: ...LX SR1530HAHLX USB One front panel USB port One internal USB header providing two USB ports System Management Intel System Management Software Table 2 Intel Server System SR1530AH SR1530AHLX SR1530HAH...

Page 27: ...use the Quick Reference Label on the inside of the chassis cover to assist in identifying components System Front Panel SR1530AH SR1530AHLX The front of the server system includes the following button...

Page 28: ...HLX System Front Panel SR1530HAHLX The front of the server system includes the following buttons and LEDs Figure 4 Front Controls and LEDs SR1530HAHLX A NIC1 LED D HDD Activity LED B NIC2 LED E USB Po...

Page 29: ...NIC 2 10 100 1000 Mb C Serial Port A H Video D NIC 1 10 100 1000 Mb I Keyboard E PCI Add in Card Slot Table 3 NIC LED Descriptions LED LED State Description Left Off No network connection Solid Amber...

Page 30: ...r installing hard drives slimline CD ROM drive or DVD ROM drive The drives must be purchased separately The following figure shows the available options Figure 6 Optional Peripherals SR1530AH SR1530AH...

Page 31: ...and one IDE connection The four SATA ports are near the front left side of the server board An IDE device can be connected to the standard IDE connector located near the SATA ports For instructions on...

Page 32: ...VD drive provided by Intel use order code AXXDVDROM To use the slimline DVD CDR drive provided by Intel use order code AXXDVDCDR Note The Intel Server System SR1530AH SR1530AHLX SR1530HAHLX does not s...

Page 33: ...m Components SR1530AH SR1530AHLX AF000970 A C D B F E G H I K A J A Rack Handles two G System Memory DIMM Sockets B PCI Cooling Fan H System Blower Fans two C Processor Air Duct I Front Panel Board D...

Page 34: ...ents SR1530HAHLX AF001575 A K F G C I J H A E D L B A Rack Handles two G PCI Add in Card Bracket B Slimline Optical Drive Bay H Processor and Heat Sink C PCI Air Baffle I Power Supply D System Blower...

Page 35: ...t Panel Connector E Intel 82541PI LAN Controller S System Front DIMM Blower Header GG SCSI HDD LED Header F PCI X 64 133 Slot 5 T System Front Processor Blower Header HH SATA Port 1 G LAN SPI Flash U...

Page 36: ...IMM Blower Header EE Front Panel Connector E PCI Express x8 Slot 5 S System Front Processor Blower Header FF SCSI HDD LED Header F Intel 82541PI Lan Controller T Chassis Intrusion Header GG SATA Port...

Page 37: ...be updated These pins should be jumpered on 1 2 for normal operation CMOS Clear If pins 2 3 are jumpered the CMOS settings will be cleared on the next reset These pins should be jumpered on 1 2 for n...

Page 38: ...r disable AHCI Mode or Configure SATA as RAID Intel Embedded Server RAID Technology II is enabled by the option Configure SATA as RAID The Intel Embedded Server RAID Technology II feature provides RAI...

Page 39: ...s 1A and 2A To operate in dual channel dynamic paging mode the following conditions must be met Populate two identical DIMMs in sockets DIMM1A and DIMM 1B Populate four identical DIMMs in each socket...

Page 40: ...18 Intel Server System SR1530AH SR1530AHLX SR1530HAHLX...

Page 41: ...n Self Test POST you will see this prompt Press F2 to enter SETUP In a third condition when CMOS NVRAM has been corrupted you will see other prompts but not the F2 prompt Warning CMOS checksum invalid...

Page 42: ...ated pick list without displaying the full list On 106 key Japanese keyboards the plus key has a different scan code than the plus key on the other keyboard but it has the same effect Enter Execute Co...

Page 43: ...y need to be followed to return the system to service See Server System References on page x for a link to necessary software and instructions Recording the Current BIOS Settings 1 Boot the computer a...

Page 44: ...ain critical information regarding jumper settings specific fixes or other information to complete the upgrade Upgrading the BIOS Follow the instructions in the readme file that came with the BIOS upg...

Page 45: ...from the normal operation position CMOS Clear by BMC at pins 1 and 2 to the CMOS Clear Force Erase position covering pins 2 and 3 Figure 13 Clear CMOS Jumper 4 Reconnect the AC power power up the sys...

Page 46: ...24 Intel Server System SR1530AH SR1530AHLX SR1530HAHLX...

Page 47: ...lustrations in this chapter show the Intel Server System SR1530AH SR1530AHLX with an optional optical drive installed The instructions for removing and installing components are the same for the Intel...

Page 48: ...ssories for the Intel Server System SR1530AH SR1530AHLX SR1530HAHLX Note the orientation in the figures below and make sure you position your bezel as shown Removing the Front Bezel Use the steps belo...

Page 49: ...l The front bezel is optional 1 At each end of the bezel line up the center notch on the bezel with the center guide on the rack handles 2 Push the bezel onto the front of the server system until it c...

Page 50: ...needed to prevent the server system from sliding on your work surface 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information on page iii 2 Turn off all periphera...

Page 51: ...he front of the chassis See letter A in the figure below 8 SR1530HAHLX Push rearward on the blue grip point at the front of the server Slide the cover back until it stops and then lift the cover upwar...

Page 52: ...See letter A in the figure below 3 SR1530AH SR1530AHLX Tighten the screw at the rear of the server See letter B in the figure 4 SR1530AH SR1530AHLX Install the two screws at the front of the server S...

Page 53: ...ired for proper airflow within the server system Removing the Processor Air Duct 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information on page iii 2 Power down...

Page 54: ...32 Intel Server System SR1530AH SR1530AHLX SR1530HAHLX Figure 20 Removing the Processor Air Duct SR1530AH SR1530AHLX Figure 21 Removing the Processor Air Duct SR1530HAHLX AF000664 AF001580...

Page 55: ...Removing the Server System Cover on page 28 4 Lower the air duct into place insert the two hooks at the front of the processor air duct into the corresponding slots on the bracket behind the two syst...

Page 56: ...tlet The silkscreen on the board for the DIMMs displays DIMM A1 DIMM A2 DIMM B1 and DIMM B2 starting from the center of the board See Memory on page 17 for a discussion of the memory requirements and...

Page 57: ...socket Align the notch on the bottom edge of the DIMM with the key in the DIMM socket See letter B in the figure 8 Insert the bottom edge of the DIMM into the socket See letter C in the figure 9 When...

Page 58: ...ipheral devices and the AC power cable 3 Remove the server system cover For instructions see Removing the Server System Cover on page 28 4 Locate the DIMM sockets See Figure 24 5 Gently spread the ret...

Page 59: ...le handling the processor 2 Avoid moving around unnecessarily Removing the Heat Sink and Processor 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information on page...

Page 60: ...3 Remove the server system cover For instructions see Removing the Server System Cover on page 28 4 Locate the processor socket and raise the socket handle completely See Figure 25 Figure 25 Lifting...

Page 61: ...he socket notches See letter A in the figure below 8 Set the processor into place as shown by letter B Figure 28 Installing the Processor Note Make sure the alignment triangle mark and the alignment t...

Page 62: ...rom the TIM on the underside of the heat sink Do not touch the TIM 2 Orient the heat sink over the processor as shown by Figure 30 The fins must be positioned as shown to provide correct airflow throu...

Page 63: ...chassis underneath the optional CD ROM drive The HDD1 drive bay is at the right side of the chassis The drives do not need to be installed in order HDD1 can be installed before HDD0 Note The server s...

Page 64: ...top of the hard drive carrier 6 Remove the screw that holds the hard drive bracket to the chassis See letter A in the figure below Save this screw You will use it to reinstall the drive assembly later...

Page 65: ...to attach the drive to the carrier See letter C in the figure Figure 33 Installing Drive into Drive Carrier SR1530AH SR1530AHLX 11 Set the drive assembly into place in the chassis See letter A in the...

Page 66: ...erneath the fan module Use caution to make sure you connect the connect cables between the server board and the hard drives The cables are labeled at each end 15 Connect the power cables to the drive...

Page 67: ...Remove the screw that holds the hard drive bracket to the chassis See letter A in the figure below Save this screw You will use it to reinstall the drive assembly later 7 Lift the drive carrier from...

Page 68: ...sis with the screw that you removed in Step 6 See letter B in the figure below Note The assembly that contains the optical drive bracket must be installed at the left side of the system Figure 37 Inst...

Page 69: ...r HDD1 can be installed before HDD0 Cautions If you install less than three drives or devices the empty drive bays must be occupied by carriers with baffles to maintain proper system cooling Note The...

Page 70: ...d drive Store the plastic retention device for future use See letter A in Figure 40 6 Remove the hard drive from its wrapper and place it on an antistatic surface 7 Set any jumpers and or switches on...

Page 71: ...ces and the AC power cable s into the server Removing a Hot Swap SATA Drive SR1530HAHLX 1 Remove the front bezel if it is installed For instructions see Removing the Front Bezel 2 Press in on the gree...

Page 72: ...m turn off the system by pressing the power button and unplug the AC power cord from the system or wall outlet Installing a Slimline Optical Drive Notes If you are replacing an optical drive see Remov...

Page 73: ...installation only Remove the knock out by rocking it back and forth See letter A in the figure below The knock out cannot be reinstalled Figure 43 Removing the Knock out from the Sheet Metal Panel 7 A...

Page 74: ...ical Drive to the Brackets 9 Slide the optical drive assembly in through the front of the chassis as shown by letter A in Figure 46 10 Reinstall the screw that you removed in step 6 11 A daisy chain c...

Page 75: ...mounting pegs that are located behind the optical drive bay The fan label should face the rear of the system See letter A in Figure 47 Figure 47 Installing the PCI Cooling Fan SR1530AH SR1530AHLX 14...

Page 76: ...zel on page 26 5 SR1530AH SR1530AHLX Note the orientation of the PCI cooling fan that is located behind the optical drive bay then lift the fan from the mounting pegs It is not necessary to disconnect...

Page 77: ...e 45 Save these screws for future use Figure 50 Attaching the Optical Drive Bracket to the Brackets 10 Remove the two screws at the back of the CD ROM or DVD ROM drive to detach the interposer board S...

Page 78: ...the brackets and interposer board for future use 14 SR1530AH SR1530AHLX Insert the PCI cooling fan onto the mounting pegs that are located behind the optical drive bay The fan label should face the re...

Page 79: ...bag labeled CD ROM Assy 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information on page iii 2 Power down the server and unplug all peripheral devices and the AC p...

Page 80: ...l Drive SR1530HAHLX 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information on page iii 2 Power down the server and unplug all peripheral devices and the AC power...

Page 81: ...rive attachment bracket as shown in the figure below Figure 56 Removing the Optical Drive from the Attachment Bracket 7 8 Optional Install the front bezel For instructions see Installing the Front Bez...

Page 82: ...instructions 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information on page iii 2 Power down the server and unplug all peripheral devices and the AC power cable...

Page 83: ...assembly into place over the add in card slot See letter A in the following figure 2 Align the three hooks in the riser assembly with the matching slots at the back of the server system See letter B i...

Page 84: ...t connector on the wrong side of the PCI riser assembly replace one connector at a time Removing a PCI Riser Card 1 Observe the safety and ESD precautions at the beginning of this book See Safety Info...

Page 85: ...cable 3 Remove the server system cover For instructions see Removing the Server System Cover 4 Disconnect any cables attached to any add in cards 5 Remove the PCI riser assembly For instructions see R...

Page 86: ...an add in card you must first take the server out of service turn off all peripheral devices connected to the system turn off the system by pressing the power button and unplug the AC power cord from...

Page 87: ...e 8 Re install the screw you removed in step 5 See letter A in the figure Figure 61 Installing an Add In Card 9 Install the PCI riser assembly into the server system For instructions see Installing th...

Page 88: ...he riser assembly See letter C in the figure 8 Re install the screw you removed in step 5 See letter A in the figure Figure 62 Removing a Full Height Add In Card Note Make sure that all empty add in c...

Page 89: ...he server system cover For instructions see Removing the Server System Cover on page 28 4 Remove the processor air duct For instructions see Removing the Processor Air Duct on page 31 5 Remove the PCI...

Page 90: ...Processor on page 38 12 Install the DIMMs For instructions see Installing DIMMs on page 34 13 Install the PCI riser assembly For instructions see Installing the PCI Riser Assembly on page 61 14 Recon...

Page 91: ...rver system cover For instructions see Removing the Server System Cover on page 28 4 Remove the processor air duct For instructions see Removing the Processor Air Duct on page 31 5 Remove the PCI rise...

Page 92: ...ord from the system or wall outlet The lithium battery on the server board powers the RTC in the absence of power When the battery starts to weaken it loses voltage and the server settings stored in C...

Page 93: ...ver System Cover on page 28 4 Remove the server s cover and locate the battery See Figure 65 5 Pull back gently on the metal tab at the top of the battery 6 Remove the battery from its socket Figure 6...

Page 94: ...ted into it fails To replace the power supply use the following instructions 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information on page iii 2 Power down the...

Page 95: ...Intel Server System SR1530AH SR1530AHLX SR1530HAHLX 73 Figure 66 Disconnecting Power Cables SR1530AH SR1530AHLX AF000969 B A C...

Page 96: ...re insert it later See letter A in the figure below 6 Lift up slightly on the front of the power supply until it clears the foot at the bottom of the chassis See letter B in the figure 7 Slide the po...

Page 97: ...rear of the system See letter A in the figure below 9 Set the front of the power supply down pushing the power supply back so it fits behind the foot at the bottom of the chassis See letter B in the...

Page 98: ...the connector on cable that is closest to power supply HDD0 power connector if a hard drive is installed here Use the center connector on the cable Optical drive power if an optical drive is installed...

Page 99: ...he following instructions 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information on page iii 2 Power down the server and unplug all peripheral devices and the AC...

Page 100: ...wer supply down pushing the power supply back so it fits behind the foot at the bottom of the chassis see letter B in the figure below Figure 71 Installing Power Supply Module into the Server System S...

Page 101: ...afety Information on page iii 2 Power down the server and unplug all peripheral devices and the AC power cable 3 Remove the server system cover For instructions see Removing the Server System Cover on...

Page 102: ...h the front panel board to the system 10 Connect the USB floppy cable if you removed it in step 6 11 Connect the USB cable and the front panel cable 12 Connect the HDD1 power and data cables Figure 73...

Page 103: ...the beginning of this book See Safety Information on page iii 2 Power down the server and unplug all peripheral devices and the AC power cable 3 Remove the server system cover For instructions see Rem...

Page 104: ...nt Panel Board SR1530HAHLX 8 Insert the replacement front panel board into the server system over the standoff see letter A in the figure below and slide the front panel board forward until the board...

Page 105: ...figure below and then install the second light pipe set see letter B in the figure below Figure 77 Installing Light Pipes on the Front Panel Board SR1530HAHLX 11 Connect the USB floppy cable if you re...

Page 106: ...be replaced The blower fans can be individually replaced if one of them fails If a fan in the power supply fails the power supply must be replaced Use the steps below to replace a system blower fan or...

Page 107: ...cket in place Save these screws You will re install them later See letter A in the figure below 7 Remove the fan cable from beneath the clip at the front of the fan bracket See letter B from the figur...

Page 108: ...86 Intel Server System SR1530AH SR1530AHLX SR1530HAHLX Figure 79 Removing Bracket and System Blower Fans from Server System SR1530AH SR1530AHLX AF000961 A C B...

Page 109: ...30AHLX 11 Install the replacement fan onto the bracket using the two screws you removed in step 9 12 Set the fan assembly into the system Insert the rear edge first and push the assembly slightly rear...

Page 110: ...System SR1530AH SR1530AHLX SR1530HAHLX Figure 81 Connecting System Blower Fans SR1530AH SR1530AHLX 15 Install the processor air duct For instructions see Installing the Processor Air Duct on page 33 A...

Page 111: ...wer button and unplug the AC power cord from the system or wall outlet 1 Observe the safety and ESD precautions at the beginning of this book See Safety Information on page iii 2 Power down the server...

Page 112: ...t the replacement fan into place The label on the fan must face the rear of the system 7 Connect the fan cable to the server board See letter A in Figure 82 8 Install the server system cover For instr...

Page 113: ...d Use the steps below to replace a system blower fan or the PCI cooling fan Replacing the System Blower Fans SR1530HAHLX 1 Observe the safety and ESD precautions at the beginning of this book See Safe...

Page 114: ...0 Connect the fan cable to the server board see letter B in the figure below 11 Install the processor air duct see letter C in the figure below Figure 85 Installing Fan into the Server System SR1530HA...

Page 115: ...and the AC power cable 3 Remove the front bezel if it is installed For instructions see Removing the Front Bezel on page 26 4 Attach the rack handle to the server system with two screws as shown in t...

Page 116: ...bezel if it is installed For instructions see Removing the Front Bezel on page 26 4 Remove the two screws holding the rack handle in place and remove the rack handle from the server system as shown in...

Page 117: ...low to determine the correct cable routing For readability separate figures for power cable routing and data cable routing are included below Make sure all necessary power and data cables are connecte...

Page 118: ...he diagram above more clear where the connectors attach to components the labels F1 F2 and F3 are used The end at the power supply itself is labeled F HDD 0 HDD 1 Optical Device B D E F3 A AF001075 F2...

Page 119: ...SR1530HAHLX 97 Data Cable Routing SR1530AH SR1530AHLX Figure 89 Data Cable Routing SR1530AH SR1530AHLX HDD 0 HDD 1 Optical Device A D E E AF001206 C B B C A D A Front panel USB D Front panel B SATA 0...

Page 120: ...nel Board F Optical Drive G Hard Disk Drive Bays H Backplane A E C D B F G G G H A Power to Server Board Main B Power to Server Board CPU C Power to Backplane D Front Panel USB E Front Panel F Optical...

Page 121: ...for each voltage For information about calculating the power usage for your configuration see Calculating Power Usage Warning Do not exceed a combined power output of 90 Watts for the 5 V and 3 3 V o...

Page 122: ...ate of change not to exceed 10 C per hour Humidity Non operating 90 relative humidity non condensing at 35 C Shock Operating Packaged 2 0 g 11 msec 1 2 sine Operational after an 24 inch free fall Acou...

Page 123: ...hat may help with your diagnostics See Server System References on page x for a link to this software If you are unable to resolve your server problems on your own see Getting Help on page 159 for ass...

Page 124: ...r board correct Are all jumper and switch settings on add in boards and peripheral devices correct To check these settings refer to the manufacturer s documentation that comes with them If applicable...

Page 125: ...isplay monitor 4 If the operating system normally loads from the hard disk drive make sure there is no CD ROM DVD disk in the optical drive 5 If the power LED does light attempt to boot from a USB flo...

Page 126: ...the power supply Some ATX power supplies have a power switch on the back of the power supply If your system has one is it turned on Remove all add in cards and see if the system boots If successful a...

Page 127: ...t them If you are using an add in video controller board do the following 1 Verify that the video works using the onboard video controller 2 Verify that the video controller board is fully seated in t...

Page 128: ...power connector plugs been forced into power connector sockets the wrong way Drive Activity Light Does Not Light Check the following Are the drive s power and signal cables properly installed Are all...

Page 129: ...t shared See the documentation that came with your PCI card s for information on changing interrupts Diagnostics pass but the connection fails Make sure the network cable is securely attached Make sur...

Page 130: ...e software is properly installed and configured for the system See the software documentation Use only an authorized copy Unauthorized copies often do not work If you are running the software from a C...

Page 131: ...t files Hard Drive s are not Recognized Check the following Make sure the drive is not disabled in BIOS Setup Make sure the drive is connected correctly and that is plugged into the power supply Make...

Page 132: ...stem power is on or off Front control panel Green Off Power is off or in sleep state S5 On Power is on or in sleep state S0 Table 9 POST Error Beep Codes Number of Beeps Reason for Beeps and Action to...

Page 133: ...cord s is considered the disconnect device to the main AC power The socket outlet that the system plugs into shall be installed near the equipment and shall be easily accessible SAFETY STEPS Whenever...

Page 134: ...cessor and heat sink may be hot if the system has been running Also there may be sharp pins and edges on some board and chassis parts Contact should be made with care Consider wearing protective glove...

Page 135: ...edes Wechselstrom Netzkabel aus der Steckdose bzw dem Netzger t um den Stromanschlu des Systems zu unterbrechen SICHERHEISMASSNAHMEN Immer wenn Sie die Geh useabdeckung abnehmen um an das Systeminnere...

Page 136: ...m die Abdeckung wieder anzubringen 1 Vergewissern Sie sich da Sie keine Werkzeuge oder Teile im Innern des Systems zur ckgelassen haben 2 berpr fen Sie alle Kabel Zusatzkarten und andere Komponenten a...

Page 137: ...eten Wechselstromsteckdose ausger stet sein ber ausreichend Platz verf gen um Zugang zu den Netzkabeln zu gew hrleisten da der Stromanschlu des Produkts haupts chlich ber die Kabel unterbrochen wird L...

Page 138: ...t install sur l arri re du syst me d verrouillez le et retirez le 2 Retirez toutes les vis des panneaux et mettez les dans un endroit s r 3 Retirez les panneaux Afin de permettre le refroidissement e...

Page 139: ...orages magn tiques il est recomand de brancher votre syst me un supresseur de surtension et de d brancher toutes les lignes de t l communications de votre modem durant un orage Muni d une prise murale...

Page 140: ...s o a cualquier tipo de superficie de metal sin pintar 6 No ponga en marcha el sistema si se han extra do las tapas del chasis Despu s de completar las seis instrucciones de SEGURIDAD mencionadas ya p...

Page 141: ...as instrucciones del fabricante El sistema est dise ado para funcionar en un entorno de trabajo normal Escoja un lugar Limpio y libre de part culas en suspensi n salvo el polvo normal Bien ventilado y...

Page 142: ...cedere all interno del sistema seguire i seguenti passi 1 Spegnere tutti i dispositivi periferici collegati al sistema 2 Spegnere il sistema usando il pulsante spento acceso dell interruttore del sist...

Page 143: ...aldati Fare attenzione alla presenza di piedini appuntiti e parti taglienti sulle schede e sul telaio consigliabile l uso di guanti di protezione Esiste il pericolo di un esplosione se la pila non vie...

Page 144: ...122 Intel Server System SR1530AH SR1530AHLX SR1530HAHLX...

Page 145: ...roduct certifications and approvals Use only the described regulated components specified in this guide Use of other products components will void the UL Listing and other regulatory approvals of the...

Page 146: ...or physical shock Isolated from strong electromagnetic fields produced by electrical devices In regions that are susceptible to electrical storms we recommend you plug your system into a surge suppre...

Page 147: ...manufacturer for servicing When replacing a hot plug power supply unplug the power cord to the power supply being replaced before removing it from the server To avoid risk of electric shock turn off t...

Page 148: ...as been running any installed processor s and heat sink s may be hot Unless you are adding or removing a hot plug component allow the system to cool before opening the covers To avoid the possibility...

Page 149: ...When replacing the battery use only the battery recommended by the equipment manufacturer Dispose of batteries according to local ordinances and regulations Do not attempt to recharge a battery Do no...

Page 150: ...zugelassenen Komponenten die im vorliegenden Handbuch angegeben werden Die Verwendung anderer Produkte oder Komponenten f hrt zum Erl schen der UL Zulassung und anderer Genehmigungen f r das Produkt D...

Page 151: ...trische Ger te erzeugt werden In gewittergef hrdeten Gebieten sollten Sie das System an einen berspannungsschutz anschlie en und bei einem Gewitter die Telekommunikationskabel zum Modem abziehen Eine...

Page 152: ...rden k nnen ffnen Sie das Netzteil nicht Im Netzteil bestehen gef hrliche Spannungen Str me und Energiequellen Schicken Sie das Ger t f r Wartungsarbeiten an den Hersteller zur ck Wenn Sie ein hot plu...

Page 153: ...le Netzkabel ab bevor Sie Komponenten ein oder ausbauen die nicht hot plug f hig sind Wenn Sie ein hot plug f higes Netzteil austauschen ziehen Sie dessen Netzkabel ab bevor Sie es aus dem Server ausb...

Page 154: ...ten Sie Platinen nur an den Kanten fest Legen Sie die Platinen nach dem Auspacken aus der Schutzh lle oder nach dem Ausbau aus dem Server mit der Bauelementseite nach oben auf eine geerdete statisch e...

Page 155: ...installer ou de mettre jour votre produit serveur Intel En cas de conflit entre les informations fournies dans ce document et celles livr es avec le produit ou publi es sur le site Web pour un produi...

Page 156: ...lles que la lumi re directe du soleil et les radiateurs l cart des sources de vibration ou des chocs physiques Isol des champs lectromagn tiques importants produits par des appareils lectriques ATTENT...

Page 157: ...re d lectricit Attention Le bouton d alimentation indiqu par le symbole de mise en veille NE COUPE PAS compl tement l alimentation secteur du syst me car le courant de veille 5 V reste actif lorsque l...

Page 158: ...les prises lectriques reli es la terre Les cordons d alimentation doivent r pondre aux crit res suivants Le cordon d alimentation doit supporter une intensit sup rieure celle indiqu e sur le produit L...

Page 159: ...en contact avec un composant chaud lors d une installation chaud prenez toutes les pr cautions n cessaires lorsque vous retirez ou installez des composants connectables chaud Attention Pour viter de...

Page 160: ...z ce que la carte ne glisse sur aucune surface Autres risques Remplacement de la pile Attention Il existe un risque d explosion si la pile n est pas correctement remplac e Lors du remplacement de la p...

Page 161: ...montar y prestar los servicios para el servidor Debe ce irse a las directrices de esta gu a y a las instrucciones de montaje de los manuales del servidor para asegurar y mantener el cumplimiento con l...

Page 162: ...ar directa y los radiadores Alejada de fuentes de vibraci n o de golpes f sicos Aislada de campos electromagn ticos producidos por dispositivos el ctricos En zonas propensas a tormentas el ctricas se...

Page 163: ...s de conexi n en funcionamiento Algunas fuentes de alimentaci n de electricidad de los servidores de Intel utilizan el polo neutral del fuselaje Para evitar riesgos de choques electricos use precauci...

Page 164: ...nte de alimentaci n deben estar conectados a los enchufes con una toma de tierra adecuada Advertencias el acceso al sistema Precauci n Para evitar lesiones personales o da os en la propiedad se aplica...

Page 165: ...i el servidor se ha estado ejecutando los procesadores y disipadores de calor estar n recalentados A no ser que est instalando o extrayendo un componente de conexi n en funcionamiento deje que el sist...

Page 166: ...acceso y deber n incluirse indicaciones que lo identifiquen como el control de alimentaci n el ctrica de toda la unidad no s lo de los servidores Para evitar el riesgo de descargas el ctricas deber i...

Page 167: ...indica para reducir al m nimo los problemas de obstrucci n de la ventilaci n y de refrigeraci n Para conseguir una refrigeraci n y corriente de aire adecuadas compruebe que cuando sistema est funcion...

Page 168: ...146 Intel Server System SR1530AH SR1530AHLX SR1530HAHLX...

Page 169: ...processor used on this server board The final configuration of your end system product may require additional EMC compliance testing For more information please contact your local Intel representative...

Page 170: ...a compatible Intel host system For information on compatible host system s refer to Intel s Server Builder Web site or contact your local Intel representative FCC ICES 003 Emissions USA Canada Verific...

Page 171: ...I Certification Taiwan GOST R Certification License Russia Belarus Certification License Belarus RRL Certification Korea IRAM Certification Argentina CNCA Certification China Ecology Declaration Inter...

Page 172: ...Australia New Zealand VCCI Marking Class A Japan BSMI Certification Number Class A Warning Taiwan GOST R Marking Russia RRL MIC Mark Korea China Compulsory Certification Mark China Table 10 Product R...

Page 173: ...will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is e...

Page 174: ...of the Canadian Department of Communications Europe CE Declaration of Conformity This product has been tested in accordance to and complies with the Low Voltage Directive 73 23 EEC and EMC Directive...

Page 175: ...ing is located on the outside rear area of the product Regulated Specified Components To maintain the UL listing and compliance to other regulatory certifications and or declarations the following reg...

Page 176: ...er supply Restriction of Hazardous Substances RoHS Compliance Intel has a system in place to restrict the use of banned substances in accordance with the European Directive 2002 95 EC Compliance is ba...

Page 177: ...hen current value of the Product if Intel is unable to repair or replace the Product If such Product is defective transportation charges for the return of Product to buyer within the USA will be paid...

Page 178: ...sole and exclusive remedies for any breach of warranty Intel is not responsible for direct special incidental or consequential damages resulting from any breach of warranty under another legal theory...

Page 179: ...e and in Asia Contact your original authorized distributor for warranty service Any replacement Product is warranted under this written warranty and is subject to the same limitations and exclusions f...

Page 180: ...158 Intel Server System SR1530AH SR1530AHLX SR1530HAHLX...

Page 181: ...ore calling fill out an Intel Server Issue Report Form A sample form can be found at http support intel com support motherboards server s3000ah For the fastest service please submit your form via the...

Page 182: ...3 2 636 9796 via Philippines New Zealand 0800 444 365 Pakistan 632 63684 15 IDD via Philippines Philippines 1 800 1 651 0117 Singapore 65 6213 1311 Taiwan 2 2545 1640 Thailand 1 800 631 0003 Vietnam 6...

Page 183: ...3 4481 Pacifictel Contact AT T USA at 1 800 225 528 Once connected dial 800 843 4481 Guatemala Contact AT T USA at 99 99 190 Once connected dial 800 843 4481 Mexico Contact AT T USA at 001 800 462 628...

Page 184: ...162 Intel Server System SR1530AH SR1530AHLX SR1530HAHLX...