Intel® Server System S9200WK Product Family Setup and Service Guide
23
3.1
Intel® Virtual RAID on CPU (Intel® VROC) Upgrade Key
–
IPC VROCSTANMOD
3.1.1
Installing the Intel® Virtual RAID on CPU (Intel® VROC) Upgrade Key
Figure 13. Installing the Intel® VROC Upgrade Key
1.
Remove the compute module to be serviced from the server chassis and place it on to an anti-static
work surface (see Section 4.2.1)
2.
Remove the right riser assembly from Riser Slot 2. (see Section 0)
3.
Remove the Intel® VROC Upgrade Key from its packaging.
4.
Locate the white 4-pin key connector near the right edge of the server board
5.
Place the key over the connector and confirm that the orientation of the key matches that of the
connector.
6.
Press the key down onto the connector.
3.1.2
Removing the Intel® Virtual RAID on CPU (Intel® VROC) Upgrade Key
Figure 14. Removing the Intel® VROC Upgrade Key
1.
Remove the compute module to be serviced from the server chassis and place it on to an anti-static
work surface (see Section 4.2.1)
2.
Remove the right riser assembly from Riser Slot 2. (see Section 0)
3.