Intel® Server System S9200WK Product Family Setup and Service Guide
41
4.5.3
M.2 SSD Installation
Figure 37. Installing the M.2 SSD
1.
If present, remove the screw from the M.2 mounting stand-off on the left side of the riser assembly.
2.
Align the notch within the SSD edge connector with the key in the M.2 connector and insert the SSD
into the connector (see Letter A).
3.
Push the free edge of the SSD towards the riser assembly (see Letter B) and secure the SSD to the M.2
mounting stand-off with the previously removed screw (see Letter C).
4.
Install the M.2 Heat Sink (see Section 4.5.4)
4.5.4
M.2 Heat Sink Installation
Figure 38. Removing the M.2 heat sink
1.
If installing a new heatsink, peel off the protective film from the thermal interface material.
2.
Align the heat sink to the riser assembly and slide into place in the direction shown (see Letter A).
3.
Ensure the screw holes are properly aligned then secure the heat sink to the riser assembly with a
screw (see Letter B).
1U Riser Assembly
2U Riser Assembly
1U Riser Assembly
2U Riser Assembly