![Intel Remote Management Module 3 User Manual Download Page 22](http://html1.mh-extra.com/html/intel/remote-management-module-3/remote-management-module-3_user-manual_2072033022.webp)
Intel® Remote Management Module 3 User Guide
Hardware Installations and Initial Configuration
Revision 1.3
11
3.3.1
Installation on Intel
®
Server Boards S5500UR and S5500WB
The Intel
®
Server Board S5500UR and S5500WB install in rack mount 1U or 2U chassis. The
same installation steps apply to both chassis types.
1. Attach the Intel
®
RMM3 to the metal fastening bracket.
2. Attach the cable from the baseboard to the RMM3 module.
3. Push out and remove the metal cover on the chassis where the NIC RJ-45 receptacle will
align.
4. Mount the RMM3 module to the header on the baseboard and secure the metal fastening
bracket to the back of the chassis as shown in figure 2. This will align the RJ-45 with the
opening in the chassis.
5. Make a note of the MAC address of the Intel
®
RMM3. It is written on a label attached to the
module (not the NIC). Keeping a record now may eliminate the need to reopen the cover
later.
6. Replace the chassis cover, attach AC power and connect a network cable to the Intel
®
RMM
NIC.
Figure 4: Installing Intel
®
RMM3 on Intel
®
Server Boards S5500UR and S5500WB