Hardware Installations and Initial Configuration
Intel® Remote Management Module 3 User Guide
Revision 1.3
10
3.
Hardware Installations and Initial Configuration
This section guides you on the hardware installations and initial configuration.
3.1
Before You Begin
Please read the Safety Information provided at the beginning of this manual before working with
your server product.
3.2
Tools and Supplies Needed
Following are the tools and supplies needed:
Phillips* (cross head) screwdriver (#1 bit and #2 bit)
Needle nosed pliers
Antistatic wrist strap and conductive foam pad (recommended)
3.3
Installation
The Intel
®
Remote Management Module 3 is currently supported on the following Intel
®
server
boards:
All SKUs of Intel
®
Server Board S5500BC
All SKUs of Intel
®
Server Board S5520HC and S5520SC
All SKUs of Intel
®
Server Board SC5520UR
The Intel
®
RMM3 Lite is currently supported on all SKU of the Intel
®
Server Board
S3420GPRX.
The Intel
®
RMM3 Lite-V is currently supported on Intel
®
Server System SR1640TH.
All SKUs of the Intel
®
Server Board S5500WB
Intel
®
Storage System SR2612UR
The Intel
®
RMM3 box contains the following components:
Intel
®
Remote Management Module
Network Interface Card (NIC) module
Plastic bag containing screws, slot bracket, 3 plastic standoffs and cabling
The installation will vary between these server boards and their chassis configurations. The
following sections detail installation instructions.
Caution:
Intel
®
RMM3, RMM3 Lite and RMM3 Lite-V are NOT hot-swappable. Before
removing or replacing it, you must first take the server out of service, turn off the
system by pressing the power button and unplug the AC power cord from the system or
wall outlet and wait for at least 10 seconds before installing the module.