Intel® Server System M50CYP2UR Family System Integration and Service Guide
123
Figure 162. Server Board Installation
16.
Verify that all cables are clear of the area in which the server board will be installed.
17.
Remove the server board from its anti-static bag
18.
Carefully lower the server board into the chassis.
19.
Slide the server board slightly towards the back of the chassis until the VGA port goes through the cut-
out on the rear panel and the screw holes align with the chassis standoffs (see Letter A).
20.
Fasten the server board to the chassis using all the screws (see Letter B). Tighten to 5 in-lb.
21.
Re-attach all cables previously removed from the server board.
22.
Install processor(s) (see
Section 6.7
23.
Install DIMMs (see
Section 6.5
24.
Reinstall all options previously removed from the server board.
25.
Reinstall riser card assemblies (see
Section 3.3.4
26.
Re-attach all internal cables previously detached from add-in cards and I/O modules.
27.
Reinstall the system fan assembly (see Section System Fan Assembly Replacement).
28.
Reinstall the power supply module(s) (see
Section 6.6
29.
Reinstall the air duct (see
Section 6.2.2
).
30.
Reinstall the system top cover (see
Section 6.1.2