Intel® Server System M50CYP2UR Family System Integration and Service Guide
120
Figure 159. 12 x 3
.5” Backplane Installation
8.
Locate the replacement backplane
Note:
Hold the backplane only by the edges. Do not push or pull on any components on the backplane.
9.
Position the backplane in alignment to the server system guides at the front of the server system.
10.
Slide the backplane down to lock it into place (see Letter A).
11.
Secure the backplane with the fastener screws as shown (see Letter B).
12.
Reinstall the drives and/or drive blanks as needed.
13.
Reinstall the air duct (see
Section 6.2.2
14.
Reinstall the system top cover (see
Section 6.1.2
6.9.3
8 x 2
.5”
Backplane and 12 x 3
.5”
Backplane Cabling
Each installed NVMe* drive must have PCIe* signals cabled to the appropriate backplane SlimSAS connector
from any of the following PCIe* signal sources:
•
Available server board x4 PCIe* SlimSAS* connectors
•
Optional tri-mode RAID add-in card
•
NVMe* riser card with SlimSAS* connectors
Each installed SAS/SATA drive must have SAS/SATA signals cabled to the appropriate backplane SAS/SATA
connector from any of the following sources:
•
Available server board two 4-port Mini-SAS HD connectors
•
Optional tri-mode RAID add-in card
•
SAS/SATA Raid module
Available riser cards, PCIe* SlimSAS cables, and SAS interposer card, along with the accessory kits, are sold
separately from the system. See the
Intel® Server M50CYP Family Configuration Guide
to determine
appropriate cables necessary to match the desired NVMe* and SAS/SATA drive configuration to a specified
source. Cables identified in the configuration guide are optimized to provide the cleanest cable routing.