Thermal Specifications
42
Document Number: 424077 Revision: 2.0Thermal/Mechanical
Specifications and Design Guidelines
6.1.3
Processor Specification for Operation Where Digital
Thermal Sensor Exceeds T
CONTROL
When the DTS value is less than T
CONTROL
, the fan speed control algorithm can reduce
the speed of the thermal solution fan. This remains the same as with the previous
guidance for fan speed control.
During operation, when the DTS value is greater than T
CONTROL
, the fan speed control
algorithm must drive the fan speed to meet or exceed the target thermal solution
performance (
Ψ
CA
) shown in
for the Intel
®
Xeon
®
processor 3400 series (95
W),
for the Intel
®
Xeon
®
processor 3400 series (45W) . To get the full
acoustic benefit of the DTS specification, ambient temperature monitoring is necessary.
Notes:
1.
The ambient temperature is measured at the inlet to the processor thermal solution.
2.
This column can be expressed as a function of T
AMBIENT
by the following equation:
Ψ
CA
= 0.29 + (45.1 - T
AMBIENT
) x 0.0181
3.
This column can be expressed as a function of T
AMBIENT
by the following equation:
Ψ
CA
= 0.29 + (45.1 - T
AMBIENT
) x 0.0105
Table 6-4.
Thermal Solution Performance above T
CONTROL
for the Intel
®
Xeon
®
Processor
3400 Series (95W)
T
AMBIENT
1
Ψ
CA
at
DTS = T
CONTROL
2
Ψ
CA
at
DTS = -1
3
45.1
0.290
0.290
44.0
0.310
0.301
43.0
0.328
0.312
42.0
0.346
0.322
41.0
0.364
0.333
40.0
0.383
0.343
39.0
0.401
0.354
38.0
0.419
0.364
37.0
0.437
0.375
36.0
0.455
0.385
35.0
0.473
0.396
34.0
0.491
0.406
33.0
0.510
0.417
32.0
0.528
0.427
31.0
0.546
0.438
30.0
0.564
0.448
29.0
0.582
0.459
28.0
0.600
0.469
27.0
0.618
0.480
26.0
0.637
0.491
25.0
0.655
0.501
24.0
0.673
0.512
23.0
0.691
0.522
22.0
0.709
0.533
21.0
0.727
0.543
20.0
0.746
0.554
Summary of Contents for BX80605X3440 - Quad Core Xeon X3440
Page 10: ...Introduction 12 Thermal Mechanical Specifications and Design Guidelines...
Page 26: ...LGA1156 Socket 28 Thermal Mechanical Specifications and Design Guidelines...
Page 78: ...Component Suppliers 78...
Page 80: ...Mechanical Drawings 80 Figure B 1 Socket Heatsink ILM Keepout Zone Primary Side for 1U Top...
Page 87: ...87 Mechanical Drawings Figure B 8 Heatsink Compression Spring...
Page 88: ...Mechanical Drawings 88 Figure B 9 Heatsink Load Cup...
Page 89: ...89 Mechanical Drawings Figure B 10 Heatsink Retaining Ring...
Page 91: ...91 Mechanical Drawings Figure B 12 Heatsink Backplate...
Page 92: ...Mechanical Drawings 92 Figure B 13 Heatsink Backplate Insulator...
Page 102: ...Socket Mechanical Drawings 104 Thermal Mechanical Specifications and Design Guidelines...
Page 106: ...Package Mechanical Drawings 108 Thermal Mechanical Specifications and Design Guidelines...