Command
Code
(Hex)
Command
Length
Response
Length
Description
CONFIG_STATUS
4
0
6
Reports the status of the last reconfiguration. You can use this command to check the
configuration status during and after configuration. The response contains the following
information:
Word
Summary
Description
0
State
Describes the most recent configuration related error.
Returns 0 when there are no configuration errors.
The error field h
CONFIG_STATUS
as 2 fields:
• Upper 16 bits: Major error code.
• Lower 16 bits: Minor error code.
Refer to the
on page 139 and
140 for more information.
1
Version
The version of the RSU data structure.
2
Pin status
• Bit [31]: Current
nSTATUS
output value (active low)
• Bit [30]: Detected
nCONFIG
input value (active low)
• Bit [29:3]: Reserved
• Bit [2:0]: The
MSEL
value at power up
3
Soft function status
Contains the value of each of the soft functions, even if
you have not assigned the function to an SDM pin.
• Bit [31:6]: Reserved
• Bit [5]:
HPS_WARMRESET
• Bit [4]:
HPS_COLDRESET
• Bit [3]:
SEU_ERROR
• Bit [2]:
CVP_DONE
• Bit [1]:
INIT_DONE
• Bit [0]:
CONF_DONE
4
Error location
Contains the error location. Returns 0 if there are no
errors.
5
Error details
Contains the error details. Returns 0 if there are no
errors.
continued...
(9)
This number does not include the command and response header.
4. Remote System Update (RSU)
UG-20205 | 2019.10.09
Intel
®
Agilex
™
Configuration User Guide
135