Intel® 460GX Chipset Software Developer’s Manual
2-5
Register Descriptions
subordinate bus number is in that range. For a type 1 cycle, the Bus Number is mapped
to AD[23:16] during the address phase.
15:11
Device Number.
This field selects one agent on the PCI bus selected by the Bus Number. Device 16 (10h)
on Bus #0 is always reserved for programming the CBN. On the bus that the chipset is
mapped into (determined by the CBN register), Device Numbers 0-31 are reserved for
the 460GX chipset components as shown in
Table 2-1
. All other devices numbers are
forwarded to the selected bus.
1 0:8
Function Number.
This field is mapped to AD[10:8] during PCI configuration cycles. This allows the
configuration registers of a particular function in a multi-function device to be accessed.
7:2
Register Number.
This field selects one register within a particular Bus, Device, and Function as specified
by the other fields in the Configuration Address Register. This field is mapped to AD[7:2]
during PCI configuration cycles.
1:0
reserved (0)
2.3.2
CONFIG_DATA: Configuration Data Register
I/O Address:
CFCh
Size:
32 bits
Default Value:
00000000h
Attribute:
Read/Write
Sticky:
No
Locked:
No
CONFIG_DATA is a 32 bit read/write window into configuration space. The portion of
configuration space that is referenced by CONFIG_DATA is determined by the contents of
CONFIG_ADDRESS.
Bits
Description
31:0
Configuration Data Window (CDW).
If bit 31 of CONFIG_ADDRESS is 1 any I/O reference that falls in the CONFIG_DATA
I/O space will be mapped to configuration space using the contents of
CONFIG_ADDRESS.
2.4
Error Handling Registers
2.4.1
SAC
2.4.1.1
SECTID: SEC ITID
Bus CBN, Device Number: 00h
Function:
0
Address Offset:
80h
Size:
8 bits
Default Value:
00h
Attribute:
Read Only/Write
Clear, Read/Write
Sticky:
Yes
Locked:
No
This register is used to capture the ITID for a single bit memory ECC error. The ITID can then be
used to determine the address of the failure. To force the ITID to be cleared and re-used, write a 1
to bit 6. This register is set anytime that the SEC bit is sent from the SDC to the SAC on a ’Retire
ITID’ command.
Summary of Contents for 460GX
Page 1: ...Intel 460GX Chipset System Software Developer s Manual June 2001 Document Number 248704 001 ...
Page 20: ...Introduction 1 8 Intel 460GX Chipset Software Developer s Manual ...
Page 80: ...System Architecture 3 8 Intel 460GX Chipset Software Developer s Manual ...
Page 90: ...System Address Map 4 10 Intel 460GX Chipset Software Developer s Manual ...
Page 98: ...Memory Subsystem 5 8 Intel 460GX Chipset Software Developer s Manual ...
Page 146: ...AGP Subsystem 7 16 Intel 460GX Chipset Software Developer s Manual ...
Page 170: ...IFB Register Mapping 9 6 Intel 460GX Chipset Software Developer s Manual ...
Page 190: ...IFB Usage Considerations 10 20 Intel 460GX Chipset Software Developer s Manual ...
Page 232: ...LPC FWH Interface Configuration 11 42 Intel 460GX Chipset Software Developer s Manual ...
Page 244: ...IDE Configuration 12 12 Intel 460GX Chipset Software Developer s Manual ...
Page 258: ...Universal Serial Bus USB Configuration 13 14 Intel 460GX Chipset Software Developer s Manual ...
Page 270: ...SM Bus Controller Configuration 14 12 Intel 460GX Chipset Software Developer s Manual ...
Page 288: ...PCI LPC Bridge Description 15 18 Intel 460GX Chipset Software Developer s Manual ...
Page 294: ...IFB Power Management 16 6 Intel 460GX Chipset Software Developer s Manual ...