MD380 User Manual Desc
ription of Function Codes
- 229 -
F
unction Code
Parameter Name
Setting Range
Default
A2-01
Rated motor power
0.1–1000.0 kW
Model
dependent
A2-02
Rated motor voltage
1–2000 V
Model
dependent
A2-03
Rated motor current
0.01–655.35 A (AC drive power
≤
55 kW)
0.1–6553.5 A (AC drive power
>
55 kW)
Model
dependent
A2-04
Rated motor
frequency
0.01 Hz to maximum frequency
Model
dependent
A2-05
Rated motor rotational
speed
1–65535 RPM
Model
dependent
A2-06
Stator resistance
(asynchronous motor)
0.001–65.535
Ω
(AC drive power
≤
55 kW)
0.0001–6.5535
Ω
(AC drive power
>
55 kW)
Model
dependent
A2-07
Rotor resistance
(asynchronous motor)
0.001–65.535
Ω
(AC drive power
≤
55 kW)
0.0001–6.5535
Ω
(AC drive power
>
55 kW)
Model
dependent
A2-08
Leakage inductive
reactance
(asynchronous motor)
0.01–655.35 mH (AC drive power
≤
55 kW)
0.001–65.535 mH (AC drive power
>
55
kW)
Model
dependent
A2-09
Mutual inductive
reactance
(asynchronous motor)
0.1–6553.5 mH (AC drive power
≤
55 kW)
0.01–655.35 mH (AC drive power
>
55 kW)
Model
dependent
A2-10
No-load current
(asynchronous motor)
0.01 A to A2-03 (AC drive power
≤
55 kW)
0.1 A to A2-03 (AC drive power
>
55 kW)
Model
dependent
A2-16
Stator resistance
(synchronous motor)
0.001–65.535
Ω
(AC drive power
≤
55 kW)
0.0001–6.5535
Ω
(AC drive power
>
55 kW)
Model
dependent
A2-17
Shaft D inductance
(synchronous motor)
0.01–655.35 mH (AC drive power
≤
55 kW)
0.001–65.535 mH (AC drive power
>
55
kW)
Model
dependent
A2-18
Shaft Q inductance
(synchronous motor)
0.01–655.35 mH (AC drive power
≤
55 kW)
0.001–65.535 mH (AC drive power
>
55
kW)
Model
dependent
A2-20
B
ack EM
F
(synchronous motor)
0.1–6553.5 V
Model
dependent
A2-27
Encoder pulses per
revolution
1–65535
1024
A2-28
Encoder type
0: A
BZ
incremental encoder
1: UVW incremental encoder
2: Resolver
3: SIN/COS encoder
4: Wire-saving UVW encoder
0
A2-30
A,
B
phase sequence
of A
BZ
incremental
encoder
0:
F
orward
1: Reserve
0
Summary of Contents for HD380-5T0.7GB
Page 1: ...High Performance AC Drive MD380...
Page 9: ......
Page 10: ...1 Safety Information and Precautions...
Page 17: ...Safety Information and Precautions MD380 User Manual 16...
Page 18: ...2 Product Information...
Page 29: ...Product Information MD380 User Manual 28...
Page 30: ...3 Mechanical and Electrical Installation...
Page 46: ...4 Operation Display and Application Examples...
Page 79: ...Operation Display and Application Examples MD380 User Manual 78...
Page 80: ...5 Function Code Table...
Page 136: ...6 Description of Function Codes...
Page 248: ...7 EMC...
Page 260: ...8 Selection and Dimensions...
Page 285: ...Selection and Dimensions MD380 User Manual 284...
Page 286: ...9 Maintenance and Troubleshooting...