Description of Function Codes
MD380 User Manual
- 236 -
F
unction Code
Parameter Name
Setting Range
Default
A6-20
Jump point of AI3 input
corresponding setting
-100.0%–100.0%
0.0%
A6-21
Jump amplitude of AI3 input
corresponding setting
0.0%–100.0%
0.5%
The AI terminals (AI1 to AI3) of the MD380 all support the corresponding setting jump
function, which fixes the AI input corresponding setting at the jump point when AI input
corresponding setting jumps around the jump range.
For example, AI1 input voltage jumps around 5.00 V and the jump range is 4.90–5.10 V.
AI1 minimum input 0.00 V corresponds to 0.0% and maximum input 10.00 V corresponds to
100.0%. The detected AI1 input corresponding setting varies between 49.0% and 51.0%.
If you set A6-16 to 50.0% and A6-17 to 1.0%, then the obtained AI1 input corresponding
setting is fixed to 50.0%, eliminating the fluctuation effect.
Group A7: User Programmable
F
unction
Group A8: Point-point Communication
F
unction Code
Parameter Name
Setting Range
Default
A8-00
Point-point communication selection
0: Disabled
1: Enabled
0
It is used to decide whether to enable point-point communication.
Point-point communication indicates direct communication between two or more MD380
AC drives by using CANlink. The master gives target frequency or target torque to one or
multiple slaves according to its own frequency or torque signal.
If multiple AC drives are connected by using CANlink cards, the terminal resistor of the
CANlink card connected to the end AC drive shall be switched on.
If point-point communication is enabled, the CANlink communication addresses of the AC
drives are automatically matched without special setting.
The point-point communication rate is set in FD-00.
F
unction Code
Name
Setting Range
Default
A8-01
Master and slave selection
0: Master
1: Slave
0
This parameter is used to determine whether the AC drive is master or slave.
At point-point communication, you only need to set the CANlink communication baud rate.
The communication addresses are allocated automatically based on whether the AC drive is
master or slave.
Summary of Contents for HD380-5T0.7GB
Page 1: ...High Performance AC Drive MD380...
Page 9: ......
Page 10: ...1 Safety Information and Precautions...
Page 17: ...Safety Information and Precautions MD380 User Manual 16...
Page 18: ...2 Product Information...
Page 29: ...Product Information MD380 User Manual 28...
Page 30: ...3 Mechanical and Electrical Installation...
Page 46: ...4 Operation Display and Application Examples...
Page 79: ...Operation Display and Application Examples MD380 User Manual 78...
Page 80: ...5 Function Code Table...
Page 136: ...6 Description of Function Codes...
Page 248: ...7 EMC...
Page 260: ...8 Selection and Dimensions...
Page 285: ...Selection and Dimensions MD380 User Manual 284...
Page 286: ...9 Maintenance and Troubleshooting...