Operation, Display and Application Examples
MD380 User Manual
- 54 -
When the AC drive is powered on again after power failure, the parameters that are selected
before power failure are displayed.
Select the required parameters by pressing
. Set the values of the parameters by
referring to the following example.
1. Determine the parameters to be displayed.
Running frequency, Bus voltage, Output voltage, Output current, Output frequency, Output
torque, PID feedback, Encoder feedback speed
2. Set the binary data.
F7-03: 0000 0000 0111 1101B, F7-04: 0010 0000 0000 0001B
3. Convert the binary data to hexadecimal data:
F7-03: 007DH, F7-04: 2001H
The values displayed on the operation panel are respectively H.1043 and H.2001
respectively for F7-03 and F7-04.
4.7 Starting or Stopping the AC Drive
4.7.1 Selecting the Start/Stop Command Source
There are three start/stop command sources, namely, operation panel control, terminal
control, and communication control. You can select the command source in F0-02.
F
unction
Code
Parameter
Name
Setting Range
Description
Default
F
0-02
Command
source
selection
0: Operation panel control
(indicator O
FF
)
1: Terminal control
(indicator ON)
2: Communication control
(indicator blinking)
Press
RUN
or
STOP
RES
to start
or stop the AC drive.
A DI terminal needs to be de
fi
ned
as the run/stop terminal.
The Modbus-RTU communication
protocol is used.
0
•
0: Operation panel control
After you press
RUN
, the AC drive starts running (the RUN indicator is ON). After you
press
STOP
RES
when the AC drive is in running state, the AC drive stops running (the
RUN indicator is OFF).
•
1: Terminal control
This control mode is applicable to scenarios where the DIP switch or electromagnetic
button is used to start or stop the application system or scenarios where the dry contact
signal is used to start or stop the AC drive.
Summary of Contents for HD380-5T0.7GB
Page 1: ...High Performance AC Drive MD380...
Page 9: ......
Page 10: ...1 Safety Information and Precautions...
Page 17: ...Safety Information and Precautions MD380 User Manual 16...
Page 18: ...2 Product Information...
Page 29: ...Product Information MD380 User Manual 28...
Page 30: ...3 Mechanical and Electrical Installation...
Page 46: ...4 Operation Display and Application Examples...
Page 79: ...Operation Display and Application Examples MD380 User Manual 78...
Page 80: ...5 Function Code Table...
Page 136: ...6 Description of Function Codes...
Page 248: ...7 EMC...
Page 260: ...8 Selection and Dimensions...
Page 285: ...Selection and Dimensions MD380 User Manual 284...
Page 286: ...9 Maintenance and Troubleshooting...