Description of Function Codes
MD380 User Manual
- 214 -
F
unction Code
Parameter Name
Setting Range
Default
FB
-03
Swing frequency cycle
0.0–3000.0s
10.0s
FB
-04
Triangular wave rising time coef
fi
cient
0.0%–100.0%
50.0%
FB-03 specifies the time of a complete swing frequency cycle.
FB-04 specifies the time percentage of triangular wave rising time to FB-03 (Swing
frequency cycle).
•
Triangular wave rising time = FB-03 (Swing frequency cycle) x FB-04 (Triangular wave
rising time coefficient, unit: s)
•
Triangular wave falling time = FB-03 (Swing frequency cycle) x (1 – FB-04 Triangular
wave rising time coefficient ,unit: s)
F
unction Code
Parameter Name
Setting Range
Default
FB
-05
Set length
0–65535 m
1000 m
FB
-06
Actual length
0–65535 m
0 m
FB
-07
Number of pulses per meter
0.1–6553.5
100.0
The preceding parameters are used for fixed length control.
The length information is collected by DI terminals. FB-06 (Actual length) is calculated by
dividing the number of pulses collected by the DI terminal by FB-07 (Number of pulses each
meter).
When the actual length FB-06 exceeds the set length in FB-05, the DO terminal allocated
with function 10 (Length reached) becomes ON.
During the fixed length control, the length reset operation can be performed via the DI
terminal allocated with function 28. For details, see the descriptions of F4-00 to F4-09.
Allocate corresponding DI terminal with function 27 (Length count input) in applications. If
the pulse frequency is high, DI5 must be used.
F
unction Code
Parameter Name
Setting Range
Default
FB
-08
Set count value
1–65535
1000
FB
-09
Designated count value
1–65535
1000
The count value needs to be collected by DI terminal. Allocate the corresponding DI terminal
with function 25 (Counter input) in applications. If the pulse frequency is high, DI5 must be
used.
When the count value reaches the set count value (FB-08), the DO terminal allocated with
function 8 (Set count value reached) becomes ON. Then the counter stops counting.
When the counting value reaches the designated counting value (FB-09), the DO terminal
allocated with function 9 (Designated count value reached) becomes ON. Then the counter
continues to count until the set count value is reached.
FB-09 should be equal to or smaller than FB-08.
Summary of Contents for HD380-5T0.7GB
Page 1: ...High Performance AC Drive MD380...
Page 9: ......
Page 10: ...1 Safety Information and Precautions...
Page 17: ...Safety Information and Precautions MD380 User Manual 16...
Page 18: ...2 Product Information...
Page 29: ...Product Information MD380 User Manual 28...
Page 30: ...3 Mechanical and Electrical Installation...
Page 46: ...4 Operation Display and Application Examples...
Page 79: ...Operation Display and Application Examples MD380 User Manual 78...
Page 80: ...5 Function Code Table...
Page 136: ...6 Description of Function Codes...
Page 248: ...7 EMC...
Page 260: ...8 Selection and Dimensions...
Page 285: ...Selection and Dimensions MD380 User Manual 284...
Page 286: ...9 Maintenance and Troubleshooting...