54
Options and programming methods
Installation and Programming Manual
Each event can be associated with 3 voice messages, selected from the message
list (refer to
Appendix D, Voice messages
).
•
Message type
•
Message A
•
Message B
This feature allows you to create messages which will be played during event-
related voice calls to contact numbers, both at the start and end of the event.
The choice of messages and the number of times they are played depends on the
“AutomaticDialer” settings.
Scenario ON
The status of all the partitions corresponds
exactly to the pre-set scenario.
The status of all least one of the
partitions does not correspond to the
pre-set scenario.
One event for each
scenario
no
ProgrammableEvt
See paragraph
6-9-1 Programmable events
no
Emergency key
One of the emergency-key duos is pressed
One event for each
emergency-key duo
Yes
Panel opened
The control-panel enclosure cover is opened
The control-panel enclosure cover is
replaced
1
no
Dislodged panel
1
no
Zone fuse fault
The zone protection fuse on the control panel
is not operational (blown)
The zone protection fuse on the control
panel restores
1
no
IBUS fuse fault
The I-BUS protection fuse is not operational
(blown)
The I-BUS protection fuse restores
1
no
Low battery
The backup battery is low
(voltage below 10.4V)
The backup battery is charged
(voltage above 11.4V)
1
no
Mains failure
The primary 230V a.c. power source is absent
(blackout)
The primary 230V a.c. power source
restores
1
no
Expansion tamper
An expansion board signals tamper conditions
Tamper conditions clear on all the
system expansion boards
1
no
Keypad tamper
A keypad signals tamper conditions
Tamper conditions clear on all the
system keypads
1
no
Reader tamper
A reader signals tamper conditions
Tamper conditions clear on all the
system readers
1
no
Sound.flash.Tamp
A sounderflasher connected to the BUS
signals tamper
All the sounderflashers connected to
the BUS reset
1
no
Nexus tamper
The GSM dialer Nexus signals tamper
Tamper conditions clear on the Nexus
1
no
Expansion loss
An expansion board cannot be found on the
BUS
All expansion boards can be found on
the BUS
1
no
Keypad loss
A keypad cannot be found on the BUS
All keypads can be found on the BUS
1
no
Reader loss
A reader cannot be found on the BUS
All readers can be found on the BUS
1
no
Sound.flash.Loss
A sounderflasher cannot be found on the BUS
All sounderflashers can be found on the
BUS
1
no
Nexus loss
The control panel is unable to communicate
the Nexus 100
Communication between the control
panel and the Nexus restores
1
no
Jamming
Wireless interference detected
Wireless interference cleared
1
no
Low battery WLS
The battery of a least one wireless detector is
running low
All the wireless detectors are running
on low batteries
1
no
WLS zone loss
Loss of at least one wireless detector has
been signaled (supervisory time-out)
All the wireless detector are present
1
no
Installer code
An Installer PIN entered at a keypad is
recognized as valid
1
Yes
Invalid code
An invalid code is entered at a keypad
1
Yes
False key
An invalid key is used at a reader
1
Yes
Nexus fault
The GSM dialer Nexus signals a fault (see
Chapter 7 - Errors and faults
)
Fault conditions clear on the Nexus
1
no
Tel. line down
The land line is not working
The land line restores
1
no
Periodic event
The Periodic Event occurs
1
Yes
Hard reset
The control panel re-initializes. The system
clock may be wrong or not working properly.
1
Yes
Call queue full
There are no more slots left in the outgoing
call queue
1
Yes
Successful call
The call is answered
1
Yes
Programming
Access to system programming is authorized
End of system programming
1
no
Ongoing call
A call is sent
A call ends
1
no
SMSMessageFailed
Nexus failed to send SMS message
1
Yes
Output fault
An output fails to switch status as
commanded
1
Yes
Table 33:
Event type
Name
Occurs when...
Restores when ...
Number of events
Pulse