60
Options and programming methods
Installation and Programming Manual
The exceptions have priority over the days of the week. For example, If a “timer
exception”, lets say 1st May, falls on a Tuesday the settings programmed for 1st
May will be applied.
Note
The “timer exceptions” cannot be programmed via keypad.
6-11
Partitions
This programming section deals with the system Partitions and the respective
options and parameters.
Via Keypad
1. Accessing the “Partitions” section:
Type-in Code
(Installer PIN)
, PROGRAMMING Partitions
.
2. Use keys
and
to select the partition then press
.
Description
This is the editable partition label (description).
Exit time
A period, expressed in minutes or seconds, during which the user must LEAVE the
partition after arming the system (see the “info” box). If you set “0” in this field,
there will be no Exit time (delay), therefore, any delayed zones, which belong to
the partition, will generate alarms if they are not in standby status when the
system arms.
Entry time
A period (expressed in minutes or seconds) that the system allows the user to
disarm the partition after violation of a delayed zone (for example, after opening
the front door). If the system is not disarmed within the set time it will generate
an alarm (see “info” box). If you set “0” in this field, there will be no Entry time
(delay), therefore, any delayed zones will generate alarms instantly if they are
violated when the system is armed.
Pre-arm time
This is the period (expressed in minutes) before an automatic arming operation
(see “info” box).
In order to comply with EN50131 instructions, the “Pre-arm” time must be set at
a value that is not “0”.
Patrol time
An “Inspection” period (expressed in minutes) which allows patrol-key/code
holders (security staff, night watchmen, etc.) to check the premises (see “info”
box ).
All the above-mentioned “times” can be programmed as follows:
1. Use keys
and
to choose whether to indicate the time in seconds or
minutes (see “info” box)..
2. Use keys
and to select the field you wish to change, then use the
number keys (
, etc.) to edit the number.
or
Use keys
or
to increase or decrease the number.
3. Press
to confirm and exit.
Timers
Select the timer you wish to associate with the “auto-am” operations.
Note
Ensure that the partition “auto-arm” option is enabled in the respective section:
Type in Code
(User)
,
Activations
.
Forced auto-arm operations may occur, generated by events active at the time of
the auto-arm operation.
Options
•
Auto-resetMemory -
if enabled by means of the
key, each partition
arming operation will reset the partition alarm/tamper memory automatically.
PROGRAMMING
Events
Timers
Partitions
PROG. PARTITIONS
PARTITION 001
PARTITION 002
PARTITION 003
If this value is
expressed in minutes,
there is an error
margin of 1 minute (for
example, if you set 5 minutes,
the period can vary between 4
and 5 minutes).