Installation and Programming Manual
First power up
37
Chapter 4
FIRST POWER UP
On first power up, the control panel initializes the parameters at default (factory
settings).
The control panel also enrolls all the peripherals it finds on the I-BUS
automatically (automatic addressing phase). The default address of all
expansions, keypads and readers is address 1, therefore, if the system is
equipped with more than one of each type of device, the automatic enrolling
operation will be erroneous. In order to allow the system to perform an accurate
auto-enrolling operation on "First power-up", work carefully through the following
steps.
Note
The default address of all peripherals (keypads, readers and expansions) is set at address
1.
ATTENTION!
When wiring the system, be careful not to allow any form of power (mains 230V
or battery) to reach the control panel or its peripherals.
1. Attach the control panel to the wall.
2. Complete the wiring of the peripherals to the BUS.
3. Connect the BUS wires to the control panel.
4. Complete the wiring and balancing of the system detectors.
5. Connect the detectors to the terminals.
6. Connect the outputs to the control panel and peripheral terminals.
7. Connect the control panel to the telephone line.
8. Connect the SmartLogos30M board to the appropriate connector on the
control panel motherboard.
9. Insert the Service jumper in the “SERV” position.
10. Connect the primary power source (230V a.c.).
11. Connect the backup battery. The first line of the display of each keypad in
the system will show the 'Maintenance' message and the keypad address at
default. On first power up (first startup), all the keypads will show "K01"
(refer to paragraph
3-1-10 Maintenance status
).
Note
If several keypads are connected to the I-BUS, their displays may be blank. If this occurs,
disregard this aspect and go directly to the next step.
12. Address the peripherals (refer to paragraph
3-3 Addressing the peripher-
als
). At least one keypad must be assigned to address 1. Using keypad 1,
initialize the addressing phase for nBy/S and nBy/X readers (refer to para-
graph
3-3-3 Addressing nBy readers
).
13. If you wish to instruct the system to learn the "balancing values" of all the
zones, initialize the procedure via the installer menu (refer to paragraph
6-
23 Default settings
,
Learn zone bal.
).
14. Remove the jumper from the “SERV” position and place it in the “RUN”
position.
15. If necessary, specify the expansion terminals simulated by the Air2-BS100
transceiver (refer to paragraph
6-5 Terminals
) as “Wireless” terminals.
16. If you decide to set up the voice and digital dialer functions and edit the
contact numbers (refer to paragraph
6-8 Telephone
).