Installation and Programming Manual
The control panel and peripherals
13
2-2-3
Events log memory
The control panel events are saved to a non-volatile semiconductor-memory
which retains data without the need of power.
The electrical characteristics of semiconductor devices diminish over time.
However, a minimum period of 40 years data retention is guaranteed.
2-2-4
I-BUS interconnections
SmartLiving control panels are equipped with a 4-wire BUS for peripheral
interconnections (2 power-supply wire and 2 data exchange wires, refer to
paragraph
3-2-1 The I-BUS line wiring
).
The intellectual property rights regarding the electrical, structural and protocol
features of the BUS are the sole property of INIM Electronics s.r.l.
The I-BUS is not a RS485 differential BUS.
2-3
Peripherals
The control panel I-BUS accommodates the following peripherals:
•
keypads (JOY/GR, JOY/MAX, nCode/G, Concept/GN)
•
Readers (nBy/S and nBy/X)
•
Expansions (Flex5)
•
Transceivers (Air2-BS100)
•
Sounderflashers (Ivy)
•
IB100 isolators
•
GSM dialer (Nexus)
2-3-1
Joy/GR and Joy/MAX Keypads
Table 6:
Device Specifications
JOY/GR
JOY/MAX
Voltage [V]
9 - 16
Typical current draw [mA]
70
90
Terminals configurable as OC outputs
2
Maximum current draw per terminal
[mA]
150
Dimensions (W x H x D) [mm]
142 x 116 x 20
Weight [g]
160
180
Table 7:
Joy - Description of parts
A
Terminal board
B
Buzzer
C
Microphone (Joy/MAX only)
D
Temperature sensor (Joy/MAX only)
E
Open-tamper microswitch
F
Backlit graphic display
G
Signaling LEDs
H
Antenna (Joy/MAX only)
I
Speaker-wire connector (Joy/MAX only)
J
Wire entry
K
Wall-mount screw locations
L
Speaker housing
M
Board supports
N
Dislodgement-tamper microswitch screw location
O
Dislodgement-tamper microswitch spring
A
B
C
E
G
H
K
L
D
F
K
K
K
K
K
K
M
M
M
I
J
O
N
JOY keypad
motherboard
JOY keypad
backplate