20
Installation
Installation and Programming Manual
3-1-3
Maximum current -
normative references
Compliancy with EN50131, CEI 79 or CEB T014 requires full observation of the
rules (relating to the applicable normative and the model of the control panel
concerned) presented in the Table below.
The system must be arranged in such a way that the current draw under normal
circumstances does not exceed the maximum current allowed and the power
source for the battery charge is always available.
3-1-4
Connecting the backup
battery
The backup battery [A] connection must be completed during the phase
described in
Chapter 4 - First power up
.
The SmartLiving 505, 515 and 1050 control panels house one lead battery @12V
7Ah.
The SmartLiving 1050L and 10100L house two lead batteries, one @12V 17Ah
and the other @12V 1.2Ah.
Note
The battery casing must have HB flame rating or higher.
Using the battery wire [B] (included), connect the battery directly to the control
panel motherboard.
ATTENTION!
Ensure that battery polarity is correct:
- black wire = negative
- red wire = positive
The backup battery is the secondary power source which powers the system
during mains failure (230Vac, 50Hz).
Once powered up, the panel will charge and monitor the batteries automatically.
The panel tests the efficiency of the batteries by simulating load current demand
at regular 4 minute intervals. If the control panel detects a voltage inferior to
10.4V (battery inefficient), it will generate an Empty battery event that will not
clear until the voltage goes back to over 11.4V.
This fault will be signaled on the yellow LED on the keypads. To view the event
details, work through the following steps:
Type-in Code
(User)
, View
, Faults
.
N L
230V ~ 50/60 Hz
AC Input
D
E
F
SmartLiving10100L
A
N
L
230V ~ 50/60 Hz
AC Input
D
E
F
SmartLiving1050L
B
N
L
230V ~ 50/60 Hz
AC
Input
D
E
F
SmartLiving 1050
Table 24:
Maximum current permitted
Norm
SmartLiving intrusion control panels
505
515
1050
1050L
10100L
EN50131-3
Maximum current
permitted
1.2A
1.2A
2.6A
3A
3.5A
Current reserved for
the battery charge
1A
1A
2A
2A
2A
CEI 79-2
Maximum current
permitted
1.2A
1.2A
2.6A
3A
3.5A
Current reserved for
the battery charge
1A
1A
2A
2A
2A
CEB T014
Maximum current
permitted
1.2A
1.2A
2.3A
2.7A
2.7A
Current reserved for
the battery charge
1A
1A
2A
2A
2A
Faults
Low battery