Installation and Programming Manual
Options and programming methods
43
Install.callback
The control panel will enable the Teleservice function if:
•
the installer calls the control panel
•
the control panel detects the ring, picks up,
recognizes the installer code and hangs up
immediately
•
the control panel calls the Teleservice number and
allows access to the system
ReaderBuzzer OFF
No reader buzzers will emit audible signals during running
entry time, exit time, output time or pre-arm time.
Keypad lockout
If a wrong code is typed-in at a keypad more than
5 times in succession, the keypad will lock for 10
minutes and show the icon:
Note
If you reset the control panel or access programming while the
keypad-lockout time is running, it will refresh to zero and start
again.
View open zones
The keypad will show the descriptions of any open zones
(zones which are not in standby status) when the partitions
disarm. Any autobypassable open-zones will be shown in white
on a black background.
OpenZonesArmLock
The control panel will not arm the partition if it detects any
open zones (zones which are not in standby status).
If there are zones with the “Auto-bypassable” or “No-
Unbypassable” attribute amongst the open-zones (refer to
paragraph
6-6 Zones
), they will be shown on the keypad as
“Not ready”. If the user goes ahead with the arming operation,
these zones will be bypassed automatically and the partition
will arm.
DTMF sensitivity
The sensitivity of incoming DTMF tones is increased.
BypassAlsoTamper
If a zone is bypassed (disabled), it will also be unable to
generate terminal tamper.
If a zone is bypassed (disabled), it will be
able to generate terminal tamper.
BypassVoiceCheck
The control panel will start the voice message 5 seconds after
dialing the respective contact number.
The control panel will not start the voice
message until it recognizes a voice at the
other end of the line.
Confirm with “*”
The control panel will consider the voice call successful when
the recipient presses
or
on the telephone
keypad.
The control panel will consider the voice
call successful as soon as it starts the voice
message.
NoUserTamp.reset
No user will be allowed to delete of the following events:
•
terminal tamper
•
control panel open-tamper
•
control panel dislodgement-tamper
•
peripheral tamper
•
peripheral loss
•
false key
Encrypt data
The control panel will encrypt data via LAN (for SmartLAN/SI
only).
Instant restoral
The restoral of the magnetic reed sensor in Air2-MC100
wireless detectors will be signaled instantly.
The restoral of the magnetic reed sensor in
Air2-MC100 wireless detectors will be
signaled with a 10 second delay
(maximum).
Teleserv. hidden
The
symbol will not be shown on the keypad display.
If Teleservice is enabled, the
symbol
will be shown on the keypad display.
LockInstall.Code
After hard reset (refer to paragraph
6-23 Default settings
), all
the control panel parameters with the exception of the installer
PIN will reset to the factory default settings.
After hard reset (refer to ), all the control
panel parameters including the installer
PIN will reset to the factory default
settings (installer PIN default is 9999).
50131ReaderLedOFF
If there are no keys present at the reader, the LEDs of nBy
readers will be Off. If a key is waved across the reader, the
status will be indicated on the LEDs for 30 seconds before
switching Off again.
During this 30 second phase, the user can hold the key in the
vicinity of the reader and select the desired shortcut indicated
by LEDs.
The reader LEDs indicate the related
status.
Table 31:
Panel options
Option
If enabled
If disabled