Installation and Programming Manual
Options and programming methods
59
•
Associate the programmable event with the telephone call you wish to receive
If you wish to activate a telephone call after 3 consecutive wrong code entries (with a
maximum of 120 seconds between each entry).
•
C0000; counter 1 will activate on activation of the “False code” Start event, with a
count of 3, 120 second autoreset time
•
The programmable event must be programmed as:
C0000
•
Associate the programmable event with the telephone call you wish to receive
If you wish to activate a telephone call and output when at least two detectors out of 5 go
into alarm status.
•
The programmable event must be programmed as (“Alarm zone 1” + “Alarm zone 2” +
“Alarm zone 3” + “Alarm zone 4” + “Alarm zone 5”)>=2
( E0000 + E0001 + E0002 + E0003 + E0004 ) >= V0002
•
Associate the programmable event with the telephone call you wish to receive and the
output you wish to activate.
6-10
Timer
This programming section deals with the 10 system Timers.
A timer can be associated with a:
•
Partition
- if a partition is associated with a timer which controls automatic-
arming operations (refer to
paragraph 5-4 Attivazioni
in the
User's Manual)
, it
will arm when the timer switches ON and disarm when the timer switches OFF.
•
Code
- if a code is associated with a timer, it will be enabled to operate the
system when the timer switches ON, and disabled when the timer switches
OFF.
•
Key -
if a key is associated with a timer, it will be enabled to operate the
system when the timer switches ON, and disabled when the timer switches
OFF.
In order to associate timers with the partitions, codes and keys, it is necessary to
access the respective control-panel programming section.
Note
The timers must be enabled/disabled by the user (refer to
paragraph 5-4 Attivazioni
in the
User's Manual)
).
When you exit the programming session (via keypad, PC or modem) all the timers will be
enabled automatically, therefore, it will be necessary to reset the timers as before.
Via Keypad
1. Accessing the “Timers” section:
Type-in Code
(Installer PIN)
, PROGRAMMING Timers
.
2. Use keys
and
to select the Timer then press
.
3. Using the same keys, select the day of the week.
4. Select “Activation” and/or “Restoral”.
5. Use keys
and
to set the time (expressed in hours and minutes) and
and
to select the number.
6. Press
to confirm and exit.
Note
It is also possible to programme timer activation or restoral only.
If you do not wish to programme the timer activation or restoral setting, enter “--:--” in
the field you do not wish to program.
Via PC
Select an item from “SmartLiving System - Timers” from the tree menu on the
left, then go to the “Parameters settings” template on the right:
The SmartLeague software programme allows you to set up 15 setting exceptions
for each timer (for holiday periods, etc.).
Each “timer exception” allows you to define different On and Off times for the
selected interval (1 or more days, 1 week, etc.). The pre-set times will be applied
for the entire interval. The system does not accept intervals which go over the
end of the year. Therefore, it is impossible to program an interval such as 12th
December to 5th January. In such situations, you must program 2 “timer
exceptions”, one from 12th to 31st December and the other from the 1st to 5th
January, both with the same On and Off settings.
TIMER 001
Activation
Restoral
TIMER 001
Sunday
Monday
Tuesday
PROGRAMMING
Telephone
Events
Timers
Timers
TIMER 001
TIMER 002
TIMER 003
TIMER 001
--:--