86
TK 56218-2-OP-EN
A help message will appear. Press the EXIT Key to return to the Alarms
Menu (
). Check the oil level and add oil as required, clear the
alarm and restart the engine.
Figure 99.
Exit Key
To return to the Main Menu press the EXIT Key. To return to the Standard
display press the EXIT Key again.
Important Alarm Notes
•
If an alarm will not clear, it may still exist. If the alarm is not corrected, it
will not clear or may be immediately set again.
•
If an alarm cannot be cleared from the Main menu, the Clear Key will not
appear. These alarms must be cleared from the Maintenance or Guarded
Access Menus.
See D
Diissp
plla
ay
yiin
ng
g a
an
nd
d C
Clle
ea
arriin
ng
g A
Alla
arrm
m C
Co
od
de
ess () for an overview or the