TK 56218-2-OP-EN
115
Table 1.
Table of Alarm Codes (continued)
COLOR CODE
DEFINITIONS:
OK TO
RUN
CHECK AS
SPECIFIED
TAKE IMMEDIATE
ACTION
Num
Description
Operator Action
06
Check Coolant Temp Sensor
Report alarm at end of day.
07
Check Engine RPM Sensor
Report alarm at end of day.
(09)
High Evaporator Temperature
Manually monitor load temperature.
Report alarm at end of day.
(10)
High Discharge Pressure
If unit is shut down repair
immediately. Otherwise, report alarm
at end of day.
11
Unit Controlling on Alternate
Sensor
Manually monitor load temperature.
Report alarm at end of day.
12
Sensor or Digital Input
Shutdown
The unit is no longer able to operate
and has been shut down. Repair
immediately.
13
Sensor Calibration Check
Manually monitor load temperature.
Report alarm at end of day.
(17)
Engine Failed to Crank
If unit is shut down repair
immediately. Otherwise, report alarm
at end of day.
(18)
High Engine Coolant
Temperature
If unit is shut down repair
immediately. Otherwise, report alarm
at end of day.
(19)
Low Engine Oil Pressure
If unit is shut down repair
immediately. Otherwise, report alarm
at end of day.
(20)
Engine Failed to Start
If unit is shut down repair
immediately. Otherwise, report alarm
at end of day.
(21)
Cooling Cycle Check
Manually monitor load temperature.
Report alarm at end of day.
(22)
Heating Cycle Check
Manually monitor load temperature.
Report alarm at end of day.
(23)
Cooling Cycle Fault
The unit is no longer able to operate
and has been shut down. Repair
immediately.