56
TK 56218-2-OP-EN
operation using the Electric Standby Selection from the Main Menu as
shown later in this section.
Switching from Electric to Diesel
N
No
otte
e:: Units equipped with the SmartPower option only.
If the Electric to Diesel Auto-Switch Enabled feature in Guarded Access is set
YES, the unit will automatically switch to Diesel Mode operation when
standby power is turned off or is no longer available.
If the Electric to Diesel Auto-Switch Enabled feature in Guarded Access is set
NO and standby power is disconnected or fails, the unit will not
automatically switch to Diesel mode. This is primarily designed to prevent
unauthorized diesel engine starts when the truck is indoors or on a ferry
where engine operation is strictly prohibited. If the Electric to Diesel Auto-
Switch Enabled feature in Guarded Access is set NO, the prompt screen
(
) will appear when standby power is turned off or is no
longer available.
Figure 50.
Standby Power is Off
If YES is selected, the display will briefly show the screen (
).
Figure 51.
Yes Selected