TK 56218-2-OP-EN
67
S
Sm
ma
arrttP
Po
ow
we
err
™
™
E
Elle
eccttrriicc S
Stta
an
nd
db
by
y O
Op
pttiio
on
n:: The Diesel/Electric Standby
selection from the Main Menu allows the operator to manually select diesel
or electric mode operation on units equipped with the electric standby
SmartPower option.
A
Ad
djju
usstt B
Brriig
gh
httn
ne
essss:: The brightness of the HMI Control Panel display can be
adjusted to allow for changing ambient light conditions.
T
Tiim
me
e:: The Time and Date held by the HMI Control Panel can be checked.
Time and Date cannot be changed from the Main Menu.
C
Clle
ea
arr A
Allll E
EC
CU
U F
Fa
au
ullttss:: Pressing this key will clear all existing Engine Control
Unit (ECU) Fault Codes on applicable units with an ECU.
Pretrip
Pretrip Test verifies unit operation. This display allows a Pretrip Test to be
selected and initiated by the operator. If the Pretrip Test is entered with the
unit not running, a Full Pretrip Test with device amp checks will be
performed. If the Pretrip Test is entered with the unit running in either diesel
or electric mode, a Running Pretrip Test is performed. Test results are
reported as PASS, CHECK, or FAIL when the Pretrip Test is completed.
Pretrip Test Conditions
•
Current unit settings are saved and restored at the end of the Pretrip Test
or if the unit is turned off and back on.
•
Pretrip Test can be run in either Diesel or Electric Mode.
•
The unit will auto switch from Diesel Mode to Electric Mode or from
Electric Mode to Diesel Mode during a Pretrip Test if these features are
enabled and the auto switch conditions occur.
Conditions Where Pretrip Tests Are Not Allowed
•
If any shutdown alarms are present. Pretrip tests are allowed with some
Check and Log alarms.
•
If the unit is in Sleep Mode.
•
If the unit is in Service Test Mode, Output Test Mode, or Evacuation
Mode.
Pretrip Test Considerations
When performing a Pretrip Test, the following issues should be considered:
•
If running a Pretrip Test on a trailer loaded with dry cargo, verify that
proper airflow can occur around the load. If the load restricts airflow,
false test results may occur. Also, these units have high refrigeration