INSTALLATION / HANDLING
53
SL, SM & SH 90, 110, 132, 150, 200, 250 &300 (50Hz)
L, H & HH 125, 150, 200, 250, 300, 350 & 400 (60Hz)
MODEL
250HP WC
60Hz
300HP WC
60Hz
350HP WC
60Hz
400HP
WC
60Hz
PRESSURE
L
100psig
H
125psig
HH
150psig
L
100psig
H
125psig
HH
150psig
L
100psig
H
125psig
HH
150psig
HH
150psig
CAPACITY
m
3
/min.
33,47
30,30
25,63
39,59
35,79
31,49
45,31
42,51
37,66
43,24
CAPACITY
ft
3
/min.
1182
1070
905
1398
1264
1112
1600
1501
1330
1527
FULL LOAD CURRENT
(MAXIMUM)
460V
A
387
351
396
464
FULL LOAD CURRENT
(MAXIMUM)
575V
A
310
281
318
371
STARTING CURRENT
(MAXIMUM)
460V
A
1885
2180
2867
3311
STARTING CURRENT
(MAXIMUM)
575V
A
1508
1744
2294
2649
*NOISE LEVEL
CAGI PNEUROP
1m
76
±
3
76
±
3
76
±
3
76
±
3
WEIGHT
O.D.P. (IP23)
lbs
21373
21969
23115
23115
WEIGHT
T.E.F.C. (IP55)
lbs
22619
23446
23446
26863
*Equivalent continuous sound pressure level (workstation) (rated load)
ELECTRICAL DATA
An independent electrical isolator should be installed adjacent to the
compressor.
Feeder cables should be sized by the customer/electrical
contractor to ensure that the circuit is balanced and not overloaded by
other electrical equipment. The length of wiring from a suitable
electrical feed point is critical as voltage drops may impair the
performance of the compressor.
Feeder cable connections to studs L1–L2–L3 on isolator should be
tight and clean.
The applied voltage must be compatible with the motor and
compressor data plate ratings.
The control circuit transformer has different voltage tappings.
Ensure that these are set for the specific applied voltage prior to
starting.
CAUTION
Never test the insulation resistance of any part of the machines
electrical circuits, including the motor without completely
disconnecting the intellisys controller.