background image

 

 

 

 

 

 

 

 

 

AIR COMPRESSOR 

OPERATING INSTRUCTION 

 

 

 

 

IMPORTANT

 

PLEASE READ CAREFULLY BEFORE USE. 
 
 

 

 
Record these numbers in the space below and retain for future reference

 

 
Power source

  240 V    50 Hz   Single Phase 

 
Model No

 

 
Serial No

________________________________________ 

 

Purchased Date: ___________________________________ 

BELT TYPE 

 

Summary of Contents for C10060

Page 1: ...READ CAREFULLY BEFORE USE Record these numbers in the space below and retain for future reference Power source 240 V 50 Hz Single Phase Model No Serial No ________________________________________ Purchased Date ___________________________________ BELT TYPE ...

Page 2: ...T SAFETY INSTRUCTIONS 2 GENERAL DESCRIPTION 3 ON RECEIPT INSPECTION 4 GENERAL REQUIREMENT 5 INSTALLATION 6 COMPRESSOR LUBRICATION 7 START UP PROCEDURE 8 MAINTENANCE CHECK LIST 9 STORAGE 10 TROUBLE SHOOTING 3 4 5 5 5 5 7 7 7 8 8 9 10 2 ...

Page 3: ... AND FUSE PROTECTION IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK 1 3 RISK OF EXPLOSION DRAIN TANK DAILY CONDENSED WATER WILL CAUSE RUSTING AND RISK OF TANK RUPTURE OR EXPLOSION DO NOT REPAIR MODIFY OR WELD TANK RETURN TO AN AUTHORIZED SERVICE CENTER IF REPLACEMENT IS REQUIRED DO NOT ADJUST REGULATOR TO RESULT IN OUTPUT PRESSURE GREATER THAN MARKED MAX PRESSURE OF ATTACHMENT PRESSURE SWITCH I...

Page 4: ...TS AUTOMATICALLY DO NOT OPERATE WITH BROKEN GUARDS OR COVERS REMOVED ANY REPAIR REQUIRED ON THE PRODUCT SHOULD BE PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL DO NOT TOUCH MOVING PARTS 1 7 RISK FROM FLYING OBJECTS ALWAYS WEAR ANSI Z87 1 APPROVED SAFETY GLASSES WITH SIDE SHIELDS WHEN USING THE AIR COMPRESSOR ALWAYS WEAR PROPER SAFETY EQUIPMENT WHILE USING COMPRESSED AIR DO NOT DIRECT HIGH PRESS...

Page 5: ...o your compressor correctly and this compressor will perform effectively 3 ON RECEIPT INSPECTION Each air compressor outfit is carefully tested and inspected before shipment Every attempt is made to ensure safe and complete shipment of our products Please inform the dealers if any deficiency was found 4 GENERAL REQUIREMENT Please ensure air compressor is installed correctly Maintain and service on...

Page 6: ... result from improper pressure setting Consult your local distributor or service center if the switch malfunctions 5 2 3 GROUNDING INSTRUCTIONS Do not modify the plug that has been provided if it does not fit the available outlet the correct outlet should be installed by a qualified electrician The plug must be plugged into an outlet that is properly installed and grounded in accordance with all l...

Page 7: ...ssor lubrication 7 5 Check that compressor is placed on stable level ground 7 6 Check that crank case breather is clean 7 7 Check that air filter is clean 7 8 Do not place any materials on or against the compressor unit itself Doing so will limit the cooling of the air compressor and could lead to premature failure 7 9 Check that the flywheel is turning in the correct direction 7 10 Open the air r...

Page 8: ...or 300 hour checklist 8 3 1 Change compressor oil and filter element 8 3 2 Check condition and alignment of belt flywheel and motor pulley Adjust belt tension if necessary or replace belt if worn 8 3 3 Check safety valve 8 3 4 Check pressure switch unloads to ensure compressor head unloads 8 3 5 Clean and blow off pump fins and motor 8 3 6 Inspect air system for leaks by applying soapy water to al...

Page 9: ...es 1 Improper oil viscosity 2 Overfilling the crankcase with oil 3 Restricted air intake filter 4 Carbon on exhaust valves 5 Worn valves 6 Worn piston rings 7 High ambient temperature and or humidity 8 Over usage of this compressor 1 Use SAE 30 non detergent compressor oil 2 Drain oil and fill to proper level 3 Clean or replace filter 4 Replace 5 Replace 6 Replace piston ring 7 Install a moisture ...

Page 10: ...red 3 Adjust for proper tension 4 Tighten as required 5 Check if unit is mounted level 6 Use SAE 30 non detergent compressor oil 7 Clean piston Check cylinder wall for scoring 8 Replace bearings Pressure switch does not unload or leak air when unit is not operating 1 Pressure switch unloading may be dirty or faulty 2 Check valve may be dirty or faulty 1 Clean repair or replace pressure switch 2 Cl...

Page 11: ...11 ...

Page 12: ...Paslode Australia Head Office 47 55 Williamson Road Ingleburn NSW 2565 Australia www paslode com au ABN 63 004 235 063 2C03 AX01 1212 12 ...

Reviews: