MAINTENANCE CHECK LIST
Before doing any maintenance or adjustments to your air compressor, the following safety
precautions should be taken.
(1)
:
DISCONNECT ELECTRICAL POWER.
(2)
:
RELEASE PRESSURE IN AIR RECEIVER.
8-1
:
Daily checklist
8-1-1
:
Check oil level.
8-1-2
:
Drain condensation from air receiver tank.
8-1-3
:
Check for any unusual noise or vibration.
8-1-4
:
Be sure all nuts and bolts are tight.
8-2
:
Weekly checklist
8-2-1
:
Clean air filter . Replace air filter if necessary.
8-2-2
:
Check oil level and top up if necessary.
8-3
:
Quarterly or 300 hour checklist
8-3-1
:
Change compressor oil and filter element.
8-3-2
:
Check condition and alignment of belt, flywheel and motor pulley.
Adjust belt tension if necessary or replace belt if worn.
8-3-3
:
Check safety valve.
8-3-4
:
Check pressure switch unloads to ensure compressor head unloads.
8-3-5
:
Clean and blow off pump fins and motor.
8-3-6
:
Inspect air system for leaks by applying soapy water to all joints. Tighten joints if
leakages are observed.
9
:
STORAGE
:
WHEN YOU HAVE FINISHED USING THE AIR COMPRESSOR
:
9-1
:
Set the “on/off” switch to “off” and unplug the cord.
9-2
:
Be sure to drain the water from the air tank.
9-3
:
Protect the electrical cord and air hose from damage.
9-4
:
Store the air compressor in a clean and dry location.