5.2

ELECTRICAL 

Please ensure that the air compressor is electrically connected in a safe and correct manner. 
Any electrical work should be carried out by an electrician and installed in a way which 
meets all applicable codes and regulations. 

Failure to connect the air compressor correctly to power source may result in serious 
personal injury or damage to the equipment.    

Please note that under normal conditions, the air compressor will operate intermittently. 
Should it be necessary to service, ensure the power source has been shut down to prevent 
personal injury or damage to the unit.    

If the supply cord is damaged, it must be replaced by a service agent in order to avoid a 
hazard. 

5-2-1

MOTOR 

Wiring must be done in a manner that full voltage is available at the motor terminals during 
startup. Use of an incorrect power source will result in premature motor failure and is not 
covered by this compressor or motor manufacturer’s warranty. 

5-2-2

PRESSURE SWITCH 

The pressure switch acts as a pilot device activating the motor. The pressure switch cut 
in/cut out has been preset at the factory, do not tamper with the settings. Never bypass or 
remove this switch, as serious damage to equipment or personal injury could result from 
improper pressure setting. Consult your local distributor or service center if the switch 
malfunctions. 

 

5-2-3

GROUNDING INSTRUCTIONS 

Do not modify the plug that has been provided, if it does not fit the available outlet, the 
correct outlet should be installed by a qualified electrician. The plug must be plugged into 
an outlet that is properly installed and grounded in accordance with all local codes. If these 
grounding instructions are not completely understood or if in doubt as to whether the 
compressor is properly grounded, have the installation checked by a qualified electrician. 

5-2-3-1

This product is for use on a nominal 240 volt circuit. 

  No adapter should be used with this product. 

5-2-4

EXTENSION CORDS 

The use of any extension cord will cause some drop in voltage and loss of power. For 
optimum performance, plug the compressor power cord directly into a grounded wall 
socket. Do not use an extension cord unless absolutely necessary. It is better to use a long 
air hose to reach area where work is being performed. If use of an extension cord can not 
be avoided, refer to the following guidelines 

                                                                         

Make sure your extension cord is in good condition. Be sure quality is sufficient to carry 
the current the unit will draw. 

5-2-5

PUMP ROTATION 

      The compressor is to be wired in a manner that the rotation of the flywheel causes the air 

to be blown over the pump. This allows the pump to cool properly.   

 

Summary of Contents for C10060

Page 1: ...READ CAREFULLY BEFORE USE Record these numbers in the space below and retain for future reference Power source 240 V 50 Hz Single Phase Model No Serial No ________________________________________ Purchased Date ___________________________________ BELT TYPE ...

Page 2: ...T SAFETY INSTRUCTIONS 2 GENERAL DESCRIPTION 3 ON RECEIPT INSPECTION 4 GENERAL REQUIREMENT 5 INSTALLATION 6 COMPRESSOR LUBRICATION 7 START UP PROCEDURE 8 MAINTENANCE CHECK LIST 9 STORAGE 10 TROUBLE SHOOTING 3 4 5 5 5 5 7 7 7 8 8 9 10 2 ...

Page 3: ... AND FUSE PROTECTION IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK 1 3 RISK OF EXPLOSION DRAIN TANK DAILY CONDENSED WATER WILL CAUSE RUSTING AND RISK OF TANK RUPTURE OR EXPLOSION DO NOT REPAIR MODIFY OR WELD TANK RETURN TO AN AUTHORIZED SERVICE CENTER IF REPLACEMENT IS REQUIRED DO NOT ADJUST REGULATOR TO RESULT IN OUTPUT PRESSURE GREATER THAN MARKED MAX PRESSURE OF ATTACHMENT PRESSURE SWITCH I...

Page 4: ...TS AUTOMATICALLY DO NOT OPERATE WITH BROKEN GUARDS OR COVERS REMOVED ANY REPAIR REQUIRED ON THE PRODUCT SHOULD BE PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL DO NOT TOUCH MOVING PARTS 1 7 RISK FROM FLYING OBJECTS ALWAYS WEAR ANSI Z87 1 APPROVED SAFETY GLASSES WITH SIDE SHIELDS WHEN USING THE AIR COMPRESSOR ALWAYS WEAR PROPER SAFETY EQUIPMENT WHILE USING COMPRESSED AIR DO NOT DIRECT HIGH PRESS...

Page 5: ...o your compressor correctly and this compressor will perform effectively 3 ON RECEIPT INSPECTION Each air compressor outfit is carefully tested and inspected before shipment Every attempt is made to ensure safe and complete shipment of our products Please inform the dealers if any deficiency was found 4 GENERAL REQUIREMENT Please ensure air compressor is installed correctly Maintain and service on...

Page 6: ... result from improper pressure setting Consult your local distributor or service center if the switch malfunctions 5 2 3 GROUNDING INSTRUCTIONS Do not modify the plug that has been provided if it does not fit the available outlet the correct outlet should be installed by a qualified electrician The plug must be plugged into an outlet that is properly installed and grounded in accordance with all l...

Page 7: ...ssor lubrication 7 5 Check that compressor is placed on stable level ground 7 6 Check that crank case breather is clean 7 7 Check that air filter is clean 7 8 Do not place any materials on or against the compressor unit itself Doing so will limit the cooling of the air compressor and could lead to premature failure 7 9 Check that the flywheel is turning in the correct direction 7 10 Open the air r...

Page 8: ...or 300 hour checklist 8 3 1 Change compressor oil and filter element 8 3 2 Check condition and alignment of belt flywheel and motor pulley Adjust belt tension if necessary or replace belt if worn 8 3 3 Check safety valve 8 3 4 Check pressure switch unloads to ensure compressor head unloads 8 3 5 Clean and blow off pump fins and motor 8 3 6 Inspect air system for leaks by applying soapy water to al...

Page 9: ...es 1 Improper oil viscosity 2 Overfilling the crankcase with oil 3 Restricted air intake filter 4 Carbon on exhaust valves 5 Worn valves 6 Worn piston rings 7 High ambient temperature and or humidity 8 Over usage of this compressor 1 Use SAE 30 non detergent compressor oil 2 Drain oil and fill to proper level 3 Clean or replace filter 4 Replace 5 Replace 6 Replace piston ring 7 Install a moisture ...

Page 10: ...red 3 Adjust for proper tension 4 Tighten as required 5 Check if unit is mounted level 6 Use SAE 30 non detergent compressor oil 7 Clean piston Check cylinder wall for scoring 8 Replace bearings Pressure switch does not unload or leak air when unit is not operating 1 Pressure switch unloading may be dirty or faulty 2 Check valve may be dirty or faulty 1 Clean repair or replace pressure switch 2 Cl...

Page 11: ...11 ...

Page 12: ...Paslode Australia Head Office 47 55 Williamson Road Ingleburn NSW 2565 Australia www paslode com au ABN 63 004 235 063 2C03 AX01 1212 12 ...

Reviews: