6

COMPRESSOR LUBRICATION 

Do not add or change oil while the compressor is in operation, use the recommended 30 weight 
non-detergent oil only. 

 

6-1

OIL FILLING 

6-1-1

Remove the oil filler plug.   

6-1-2

Slowly pour the proper oil into the pump crankcase.    

6-1-3

Always keep oil level between the marks “HIGH” and “LOW” level on the oil stick or on   

the red circle of the sight glass. 

7

START UP PROCEDURE 

    Do not attempt to operate the air compressor unit without first checking the oil level in the pump, 

add oil as required. Serious damage may result from use without oil. 

7-1

Check to see that nuts and bolts are all snug, this must be done as some fasteners may 

become loose in transit. 

7-2

Check to see if the belt is installed with proper tension. 

7-3

Check belt tightness so that when pressure is applied at the center, there is 1/2” slack. 

 
 
 
 
 
 
 
 

7-4

Check that type and oil level is correct, user proper compressor lubrication. 

7-5

Check that compressor is placed on stable, level ground. 

7-6

Check that crank case breather is clean. 

7-7

Check that air filter is clean. 

7-8

Do not place any materials on or against the compressor unit itself. 
Doing so will limit the cooling of the air compressor and could lead to   
premature failure. 

7-9

Check that the flywheel is turning in the correct direction. 

7-10

Open the air receiver outlet ball valve and start the unit. Allow the unit to operate for a 

minimum of twenty minutes in this no load condition. 

7-11

After running the compressor for twenty minutes, close the ball valve and allow the 

unit to reach maximum operating pressure. Ensure that the compressor shuts down 
at the preset maximum pressure, and the head pressure is released through 
pressure switch. 

7-12

Check the air compressor and piping systems for leakages, and correct as required. 

7-13

Shut off of all power to the air compressor before attempting any repair or maintenance. 

7-14

Stop the compressor and check the oil level thru oil gauge. Add oil as required. 

7-15

Your compressor is ready for use. 

 

Summary of Contents for C10060

Page 1: ...READ CAREFULLY BEFORE USE Record these numbers in the space below and retain for future reference Power source 240 V 50 Hz Single Phase Model No Serial No ________________________________________ Purchased Date ___________________________________ BELT TYPE ...

Page 2: ...T SAFETY INSTRUCTIONS 2 GENERAL DESCRIPTION 3 ON RECEIPT INSPECTION 4 GENERAL REQUIREMENT 5 INSTALLATION 6 COMPRESSOR LUBRICATION 7 START UP PROCEDURE 8 MAINTENANCE CHECK LIST 9 STORAGE 10 TROUBLE SHOOTING 3 4 5 5 5 5 7 7 7 8 8 9 10 2 ...

Page 3: ... AND FUSE PROTECTION IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK 1 3 RISK OF EXPLOSION DRAIN TANK DAILY CONDENSED WATER WILL CAUSE RUSTING AND RISK OF TANK RUPTURE OR EXPLOSION DO NOT REPAIR MODIFY OR WELD TANK RETURN TO AN AUTHORIZED SERVICE CENTER IF REPLACEMENT IS REQUIRED DO NOT ADJUST REGULATOR TO RESULT IN OUTPUT PRESSURE GREATER THAN MARKED MAX PRESSURE OF ATTACHMENT PRESSURE SWITCH I...

Page 4: ...TS AUTOMATICALLY DO NOT OPERATE WITH BROKEN GUARDS OR COVERS REMOVED ANY REPAIR REQUIRED ON THE PRODUCT SHOULD BE PERFORMED BY AUTHORIZED SERVICE CENTER PERSONNEL DO NOT TOUCH MOVING PARTS 1 7 RISK FROM FLYING OBJECTS ALWAYS WEAR ANSI Z87 1 APPROVED SAFETY GLASSES WITH SIDE SHIELDS WHEN USING THE AIR COMPRESSOR ALWAYS WEAR PROPER SAFETY EQUIPMENT WHILE USING COMPRESSED AIR DO NOT DIRECT HIGH PRESS...

Page 5: ...o your compressor correctly and this compressor will perform effectively 3 ON RECEIPT INSPECTION Each air compressor outfit is carefully tested and inspected before shipment Every attempt is made to ensure safe and complete shipment of our products Please inform the dealers if any deficiency was found 4 GENERAL REQUIREMENT Please ensure air compressor is installed correctly Maintain and service on...

Page 6: ... result from improper pressure setting Consult your local distributor or service center if the switch malfunctions 5 2 3 GROUNDING INSTRUCTIONS Do not modify the plug that has been provided if it does not fit the available outlet the correct outlet should be installed by a qualified electrician The plug must be plugged into an outlet that is properly installed and grounded in accordance with all l...

Page 7: ...ssor lubrication 7 5 Check that compressor is placed on stable level ground 7 6 Check that crank case breather is clean 7 7 Check that air filter is clean 7 8 Do not place any materials on or against the compressor unit itself Doing so will limit the cooling of the air compressor and could lead to premature failure 7 9 Check that the flywheel is turning in the correct direction 7 10 Open the air r...

Page 8: ...or 300 hour checklist 8 3 1 Change compressor oil and filter element 8 3 2 Check condition and alignment of belt flywheel and motor pulley Adjust belt tension if necessary or replace belt if worn 8 3 3 Check safety valve 8 3 4 Check pressure switch unloads to ensure compressor head unloads 8 3 5 Clean and blow off pump fins and motor 8 3 6 Inspect air system for leaks by applying soapy water to al...

Page 9: ...es 1 Improper oil viscosity 2 Overfilling the crankcase with oil 3 Restricted air intake filter 4 Carbon on exhaust valves 5 Worn valves 6 Worn piston rings 7 High ambient temperature and or humidity 8 Over usage of this compressor 1 Use SAE 30 non detergent compressor oil 2 Drain oil and fill to proper level 3 Clean or replace filter 4 Replace 5 Replace 6 Replace piston ring 7 Install a moisture ...

Page 10: ...red 3 Adjust for proper tension 4 Tighten as required 5 Check if unit is mounted level 6 Use SAE 30 non detergent compressor oil 7 Clean piston Check cylinder wall for scoring 8 Replace bearings Pressure switch does not unload or leak air when unit is not operating 1 Pressure switch unloading may be dirty or faulty 2 Check valve may be dirty or faulty 1 Clean repair or replace pressure switch 2 Cl...