![Ingersoll-Rand Sierra H 125 Operation And Maintenance Manual Download Page 51](http://html1.mh-extra.com/html/ingersoll-rand/sierra-h-125/sierra-h-125_operation-and-maintenance-manual_2059183051.webp)
INSTALLATION / HANDLING
47
SL, SM & SH 90, 110, 132, 150, 200, 250 &300 (50Hz)
L, H & HH 125, 150, 200, 250, 300, 350 & 400 (60Hz)
MODEL
S200 AC
lD
50Hz
S250 AC
lD
50Hz
S300 AC
lD
50Hz
PRESSURE
L
7,0 bar
M
8,5 bar
H
10,0 bar
L
7,0 bar
M
8,5 bar
H
10,0 bar
H
10,0 bar
CAPACITY
m
3
/min.
35,00
32,62
27,41
45,23
41,52
35,47
43,32
CAPACITY
ft
3
/min.
1236
1152
968
1597
1466
1253
1530
FULL LOAD CURRENT
(MAXIMUM)
380V
A
431
536
653
FULL LOAD CURRENT
(MAXIMUM)
415V
A
426
517
591
STARTING CURRENT
(MAXIMUM)
380V
A
3077
3513
3965
STARTING CURRENT
(MAXIMUM)
415V
A
3130
3482
4000
*NOISE LEVEL
CAGI PNEUROP
1m
79
±
3
79
±
3
79
±
3
WEIGHT
O.D.P. (IP23)
kg
4582
4702
4762
WEIGHT
T.E.F.C. (IP55)
kg
5222
5262
5512
*Equivalent continuous sound pressure level (workstation) (rated load)