OPERATING INSTRUCTIONS
59
SL, SM & SH 90, 110, 132, 150, 200, 250 &300 (50Hz)
L, H & HH 125, 150, 200, 250, 300, 350 & 400 (60Hz)
[ ] denotes alternative units for reference.
–ALARM HISTORY–
#
6,90
bar
[100]
[psi]
ALARM HISTORY 1
MAIN MOTOR OVERLOAD
READY TO START
ALARM HISTORY 2
HIGH AIREND DISCH TEMP
STATUS
MAIN MENU
SELECT
The calibration screen can be exited by pressing either the STATUS
or MAIN MENU buttons. If no buttons are pressed within 30 seconds,
the display will return to the CURRENT STATUS screen.
ALARM HISTORY
Alarm History displays each of the Alarm messages for the last 15
Alarms experienced by the machine. It also gives access to displaying
the machine operating conditions that existed at the time of each Alarm.
The first one shown, “Alarm History 1”, was the most recent Alarm to
occur. Note that multiple, consecutive EMERGENCY STOP Alarms
are not recorded as separate Alarms, only the first one will be shown.
Each of the last 15 Alarm messages can be seen by moving the
Alarm History list up and down using the arrow buttons. Pressing the
SELECT button when one of the Alarms is highlighted will display the
list of machine values that existed at the time that particular Alarm
occurred.
[ ] denotes alternative units for reference.
ALARM HISTORY 1
#
6,90
bar
[100]
[psi]
PACKAGE DISCH PRESSURE
13,7 bar [198 psi]
READY TO START
PACKAGE DISCHARGE TEMP
40
_
C [104
_
F]
STATUS
MAIN MENU
ALARM HIST.
The name and value of each of the items listed below can be seen
by moving the list up and down using the arrow buttons. Pressing the
ALARM HIST. button will return the display to the ALARM HISTORY
screen.
ALARM HISTORY Items
Discharge Pressure
2nd Stage Inlet Press
2nd Stage Inlet Temp
2nd Stage Discharge Press
2nd Stage Discharge Temp
Bearing Oil Temperature
Bearing Oil Pressure
Inlet Vacuum
Inlet Filter
Oil Filter Pressure Drop
Total Hours
Loaded Hours
Package Discharge Pressure
Alarm histories can be exited by pressing either the STATUS or
MAIN MENU buttons. If no buttons are pressed within 30 seconds, the
display will return to the CURRENT STATUS screen.
[ ] denotes alternative units for reference.
WARNING
6,90
bar
[100]
[psi]
CHANGE INLET FILTER
RUNNING UNLOADED
PRESS RESET TWICE
MODE: MOD/ACS
STATUS
MAIN MENU
RESET
When a Warning occurs, the word WARNING will flash on the
display screen and appear in large letters as shown above. The display
message will indicate what caused the warning.
If multiple Warnings exist, the small up/down arrows will appear in
the upper right corner of the display screen. The multiple Warnings can
be seen by pressing the up and down arrow buttons. Pressing the
STATUS button will display the CURRENT STATUS screen with the
WARNING button indicating that a Warning still exists.