2.1.5 Setting of PC
Use the computer set as below during testing. Otherwise control devices may make operation
errors.
After K2 installation, the computer is automatically set as below. Some of setting items below
may be unused for some OS:
1
)
Do not use ‘Power Options (Power Saving function) ’ of PC
Please check that the all following items in ‘Power Options Properties’ set as ‘Never’.
・
Turn off monitor
・
Turn off hard disks
・
System standby
2
)
Disable the Windows tasks unnecessary for the controls that may be periodically executed.
・
System Restore (SR)
・
Power Efficiency Diagnostics (Analyze System)
3
)
Do not use the visual effects that load the computer, e.g., settings below:
・
Disable ‘Enable desktop composition’.
・
Disable ‘Display window content during dragging’.
・
Disable ‘Enable transparency’.
4
)
Windows update setting is set to ‘Check for updates but let me choose whether to install them’.
During testing, do not execute such programs as shown below since they load the computer:
1
)
Do not use antivirus software or Windows Update or other program update.
2
)
Do not use applications that use antivirus software scan or other computer resources.
Operation of K2 is guaranteed only with the conditions of PC at shipment. If operation system
of PC is updated or any other software is installed after shipment, or under conditions other than
those at shipment, operation of K2 is not guaranteed.
Summary of Contents for K2-CE
Page 4: ......
Page 34: ...2 6 Step 2 The initial screen of installation appears Press the button of Next...
Page 38: ...2 10 Step 2 The initial screen of installation appears Press the button of Next...
Page 49: ...2 21 Step 2 The initial screen of installation appears Press the button of Next...
Page 55: ...2 27 Step 3 The screen displaying the message of Uninstall or change a program appears...
Page 58: ...2 30 Step 3 The screen displaying the message of Uninstall or change a program appears...
Page 81: ......
Page 82: ......
Page 92: ...4 3 4 2 2 Exit from Application 1 K2 Launcher Press the button Close on the screen...
Page 107: ...4 18 Step 3 A graph of the page displayed currently appears in the display...
Page 110: ...4 21 Step 3 Additional graph appears on the currently displayed page...
Page 121: ...4 32 Step3 Press the Mark button to mark the cursor data displayed in the list...
Page 141: ...4 52 Step 2 Press Yes when a dialog of message for assuring appears...
Page 149: ...4 60 Step 5 Press the OK button...
Page 170: ...4 81 Step 9 Press OK after completing of the necessary settings...
Page 172: ...4 83 Report of testing result generated by Report Generator...
Page 196: ...6 12 Step 3 Select desired data file Some files can be selected at a time...
Page 201: ...6 17 Step 3 Select desired data file Some files can be selected at a time...
Page 212: ...7 6 7 2 2 Standards Mode Procedures Step 1 Press the button of Standards...
Page 217: ...7 11 7 2 3 Test files mode Procedures Step 1 Press the button of Test files...