4-2
4.1.3 Preparation before running the motor for a test--Setting function code data
Before starting running the motor, set function code data specified in Table 4.1 to the motor ratings
and your system design values. For the motor, check the rated values printed on the nameplate of
the motor. For your system design values, ask system designers about them.
For details about how to change function code data, refer to Chapter 3, Section 3.4 "Setting
the Function Codes." If the motor capacity is different from the inverter capacity, refer to
Chapter 5, function code H03.
Table 4.1 Settings of Function Code Data before Driving the Motor for a Test
Function code
Name
Function code data
Factory setting
F 04
Base frequency
60.0 (50.0) (Hz) (Note)
F 05
Rated Voltage (at base
frequency)
0 (V)
(Output voltage interlocked
with the source voltage)
P 02
Motor Parameter
(Rated capacity)
Applicable motor rated
capacity
P 03
Motor Parameter
(Rated current)
Rated current of applicable
motor
P 99
Motor Selection
Motor ratings (printed on the
nameplate of the motor)
0: Characteristic of motor,
0 (standard 8-series
motors)
F 03
Maximum frequency
60.0 (50.0) (Hz) (Note)
F 07
Acceleration time 1*
6.00 (sec)
F 08
Deceleration time 1*
System design values
* For a test-driving of the motor,
increase values so that they
are longer than your system
design values. If the set time
is short, the inverter may not
start running the motor.
6.00 (sec)
(Note) Values in parentheses ( ) in the above table denote default settings for the EU version except three-phase
200 V series.
Summary of Contents for Jaguar CUB
Page 47: ...3 5 Figure 3 2 Alarm Mode Status Transition...
Page 77: ...5 4...
Page 78: ...5 5 E codes Extension Terminal Functions...
Page 80: ...5 7...
Page 81: ...5 8 C codes Control Functions of Frequency...
Page 84: ...5 11 y codes Link Functions...
Page 149: ...8 5 8 3 Common Specifications...
Page 150: ...8 6...
Page 153: ...8 9 8 5 External Dimensions 8 5 1 Standard Models...
Page 154: ...8 10...
Page 155: ...8 11 8 5 2 Models Available on Order EMC Filter Built in Type...
Page 156: ...8 12...